PFCS-440 Fixed Displacement Piston Pump

PFCS-440 Fixed Displacement Piston Pump

At Rexton Hydraulic, we supply, install and maintain the full PFCS pump range. For PFCS-440, we can help you choose the correct variant for your needs, guide you through the installation setup, and repair services the pumps.
 

  • Series: PFCS Pump
  • Displacement  468 ml/rev – 588 ml/rev
  • Nominal Pressure 500 Bar
  • Maximum Pressure 700 Bar
  • Maximum Speed 2200 RPM
  • Fixed Displacement Pump
  • Open Circuit Pump

Share Product:

The PFCS-440 Fixed Displacement Axial Piston Pump by Oilgear is a heavy-duty hydraulic pump that serves in applications requiring large fluid volume, high pressure, and long-term reliability. Its displacement of 468 ml/rev means that this pump serves best in high-pressure industrial work, such as forging presses, rubber pad presses, die forging, and other heavy-duty hydraulic systems that depend on consistent and predictable flow and power.

This model operates on an open-loop circuit and is designed for arduous applications. It provides for a continuous pressure rating up to 700 bar, operating at up to 2200 RPM, to give it strength and durability to sustain hard work and long hours of service.

Inside, PFCS-440 uses a rugged design: 18 hardened steel pistons are housed in stationary cylinders, eliminating centrifugal stress and reducing wear. The pump features a double-sided, counterbalanced swashblock with replaceable wear plates, which simplifies maintenance and extends service life. Its stationary-piston design and sturdy valve arrangement provide excellent resistance to contamination and support use with low-viscosity or water-based hydraulic fluids - making it versatile for a variety of fluid-power systems.

Due to its fixed-displacement nature, PFCS-440 provides a constant, repetitive flow in every revolution of the shaft. It thus assures predictability even under very stressful loads and becomes ideal for those applications in which repeatability, pressure stability, and reliability are key. Its design reduces complexity, improves uptime, and simplifies hydraulic circuit control.

Engineers and system designers alike benefit from robust construction and flexible installation options afforded by PFCS-440. A solid frame and a standard mounting design make the integration into heavy-duty hydraulic installations straightforward. Whether applied in forging presses, test benches, intensifier units, or large mobile hydraulic platforms-this pump stands up to the challenge.

Technical Specifications

PVG FAMILY SPECIFICATIONS

FRAME SIZE MODEL B-FRAME C-FRAME D-FRAME
PVG-048 PVG-065 PVG-075 PVG-100 PVG-130 PVG-150 PVG-180
DRIVE Maximum (RPM) 2700 2700 2700 2400 2400 2400 2400
Minimum (RPM) 600 600 600 600 600 600 600
Torque to turn shaft (ft. lbs.) 9 9 9 24 24 40 50
Rotational Moment of Inertia (lbs.-in2) 21 21 21 50 47 150 152
OUTPUT1 Pressure (PSIA) Peak 5800 5800 4250 5800 4250 5800 5800
Continuous 5000 5000 3750 5000 3750 5000 5000
Minimum 100 100 100 100 100 100 100
Nominal Volume (GPM) at 1800 RPM and Rated Pressure For Full Displacement 21.1 28.8 33.3 42.4 57.6 63.0 78.0
CASE2 Maximum Pressure (PSI) w/ Standard Shaft Seal 25 25 25 25 25 25 25
Minimum Drain Line Hose Size #16 SAE #16 SAE #16 SAE #16 SAE #16 SAE #16 SAE #16 SAE
CONTROLS3 Minimum Pressure (PSI) Pressure Controls – Minimum Compensator Setting 200 200 200 200 200 250 250
Volume Controls (VS, VM) – Minimum Pilot Pressure 500 500 500 500 500 500 800
Maximum Pilot Pressure (PSI) Volume Control – VS 600 600 600 600 600 600 N/A
Volume Control – VM 1000 1000 1000 1000 1000 1000 1000
Stroking Rate (MSEC) at Rated Pressure, Pressure Controls (Minimum) On Stroke 40 40 40 40 40 45 45
Off Stroke 50 50 50 50 50 60 60
Volume Controls (VS, VM) On Stroke 250 250 250 250 250 250 250
Off Stroke 250 250 250 250 250 250 250
FLUID4 Viscosity (SSU) Minimum 65 65 65 65 65 65 65
Maximum 2000 2000 2000 2000 2000 2000 2000
TEMPERATURE5 Fluid Operating Range (F˜) 14 to 190 14 to 190 14 to 190 14 to 190 14 to 190 14 to 190 14 to 190
Fluid Minimum Starting (F˜) -40 -40 -40 -40 -40 -40 -40
Fluid Maximum at Case Drain Port (F˜) 230 230 230 230 230 230 230