Oilgear PVV-250 Variable Displacement Axial Piston Pump
Oilgear PVV-250 Variable Displacement Axial Piston Pump
Rexton Hydraulic covers the PVV-250 full service: sales, spec support, installation guidance, maintenance and repair throughout the life of the pump. We help you choose the right control version, keep the system clean and set up correctly and monitor performance so your hydraulic system runs at maximum uptime and reliability.
- Series: PVV Pump
- Displacement 200.0 cc/rev – 540.0 cc/rev
- Nominal Pressure 301 Bar
- Maximum Pressure 501 Bar
- Maximum Speed 2000 RPM
- High-Pressure Pump
- Open Circuit Pump
Share Product:
Oilgear PVV-250 Variable Displacement Axial Piston Pump can handle heavy flows, high pressures and long duty cycles. With a maximum displacement of 250 cc/rev, this pump is designed for large industrial and mobile applications where high flow and high pressure are key. It’s an open-loop circuit pump built for durability, precision and high performance.
This is rated for continuous pressure up to around 345 bar (5,000 psi) and peak pressure up to 400 bar (5,800 psi), the PVV-250 can handle tough hydraulic jobs. Depending on RPM, the rated flow at full displacement is approximately 59 gpm (~223 l/min) at 1,000 RPM, 72 gpm (~273 l/min) at 1,200 RPM and about 109 gpm (~413 l/min) at 1,800 RPM. This high flow capability is for heavy duty equipment like large presses, mining systems, material-handling installations and large hydraulic power units.
Oilgear pumps are engineered with long life and high performance in mind. The cylinder barrel is supported by hydrodynamic bearings which reduce internal wear and friction under heavy loads. The rotating group has hardened contact surfaces (“hard-on-hard” design) which resist contamination and allow reliable operation with low viscosity fluids. These features reduce downtime, extend maintenance intervals and deliver high performance in harsh environments.
The control response is another notable feature. The PVV-250 has sophisticated displacement control which allows smooth and rapid output changes to system demands. This makes it a good fit for applications where hydraulic loads change quickly or where high precision is required, like material handling, large mobile fleets or industrial test rigs.
Although this is a high capacity pump, the frame size is relatively compact for its performance class. Engineers can choose from multiple shaft configurations, rotation directions and porting options (top, bottom or rear). This flexibility makes it easy to integrate the pump into new systems or retrofit into existing hydraulic setups.
Technical Specifications
PVG FAMILY SPECIFICATIONS
| FRAME SIZE MODEL | B-FRAME | C-FRAME | D-FRAME | ||||||
| PVG-048 | PVG-065 | PVG-075 | PVG-100 | PVG-130 | PVG-150 | PVG-180 | |||
| DRIVE | Maximum (RPM) | 2700 | 2700 | 2700 | 2400 | 2400 | 2400 | 2400 | |
| Minimum (RPM) | 600 | 600 | 600 | 600 | 600 | 600 | 600 | ||
| Torque to turn shaft (ft. lbs.) | 9 | 9 | 9 | 24 | 24 | 40 | 50 | ||
| Rotational Moment of Inertia (lbs.-in2) | 21 | 21 | 21 | 50 | 47 | 150 | 152 | ||
| OUTPUT1 | Pressure (PSIA) | Peak | 5800 | 5800 | 4250 | 5800 | 4250 | 5800 | 5800 |
| Continuous | 5000 | 5000 | 3750 | 5000 | 3750 | 5000 | 5000 | ||
| Minimum | 100 | 100 | 100 | 100 | 100 | 100 | 100 | ||
| Nominal Volume (GPM) at 1800 RPM and Rated Pressure For Full Displacement | 21.1 | 28.8 | 33.3 | 42.4 | 57.6 | 63.0 | 78.0 | ||
| CASE2 | Maximum Pressure (PSI) w/ Standard Shaft Seal | 25 | 25 | 25 | 25 | 25 | 25 | 25 | |
| Minimum Drain Line Hose Size | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | ||
| CONTROLS3 | Minimum Pressure (PSI) | Pressure Controls – Minimum Compensator Setting | 200 | 200 | 200 | 200 | 200 | 250 | 250 |
| Volume Controls (VS, VM) – Minimum Pilot Pressure | 500 | 500 | 500 | 500 | 500 | 500 | 800 | ||
| Maximum Pilot Pressure (PSI) | Volume Control – VS | 600 | 600 | 600 | 600 | 600 | 600 | N/A | |
| Volume Control – VM | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | ||
| Stroking Rate (MSEC) at Rated Pressure, Pressure Controls (Minimum) | On Stroke | 40 | 40 | 40 | 40 | 40 | 45 | 45 | |
| Off Stroke | 50 | 50 | 50 | 50 | 50 | 60 | 60 | ||
| Volume Controls (VS, VM) | On Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | |
| Off Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | ||
| FLUID4 | Viscosity (SSU) | Minimum | 65 | 65 | 65 | 65 | 65 | 65 | 65 |
| Maximum | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | ||
| TEMPERATURE5 | Fluid Operating Range (F˜) | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | |
| Fluid Minimum Starting (F˜) | -40 | -40 | -40 | -40 | -40 | -40 | -40 | ||
| Fluid Maximum at Case Drain Port (F˜) | 230 | 230 | 230 | 230 | 230 | 230 | 230 | ||