Oilgear DN Type 300 HP Legacy Hydraulic Pump

Oilgear DN Type 300 HP Legacy Hydraulic Pump

Rexton Hydraulic deals in sales and repair services for the Oilgear DN Type 230 HP Legacy Hydraulic Pump. This is a legacy variable displacement hydraulic pump designed for high-power, high-pressure industrial applications requiring precise control and long-term reliability.
 

  • Series: D Type Pumps
  • Displacement 21.36 – 802.96 cc/rev
  • Continous Pressure 1500 – 4000 psi
  • Maximum Speed 900 – 1800 RPM
  • Variable Displacements Piston Pump
  • Open Circuit Pump

Share Product:

Oilgear DN Type 300 HP Legacy Hydraulic Pump is designed for high-power applications and environments where a high level of hydraulic power is required. The DN Series of pumps was developed to support the high functionality and continuous operation of high-pressure machines. The design of the DN Type 300 HP pump reflects a maximal operating speed of 1200 RPM and a continuous working press Maximally of 3000 psi. The machine is capable of delivering high and continuous horsepower.

The Variable Displacement Legacy Pump has a variable displacement feature that makes the pump able to control the amount of fluid being discharged autonomously depending on the requirement of the system. The pump will not run at full capacity all the time but will vary the amount of displacement according to the amount of resistance. In turn, the result will help in extending the lifespan of the entire system.

The Oilgear DN Type 300 HP pump also features a strong radial rolling piston mechanism that is suitable for high torque and high-pressure applications. The two-way hydraulic system supports reversed flow funtionality. This allows it to work with fewer direction-control valves. The pump is beneficial in that it results in smoother system performance. This is because it results in low-pressure shock. The system also is beneficial because it increases system response accuracy.

Even though the DN Type 300 HP is considered a legacy product, this does not stop it from being a reliable option for maintaining, overhauling, and upgrading existing systems that originally used Oilgear’s DN Series technology. In fact, many industrial facilities still continue to use this particular pump due to its mechanical durability, predictable power output, and historical success in continuous duty operations. Even though there might be more advanced models available for upgrading existing systems, such as enhanced pump technology, this particular model is not a bad option regarding compatibility and hydraulic precision.

Technical Specifications

PVG FAMILY SPECIFICATIONS

FRAME SIZE MODEL B-FRAME C-FRAME D-FRAME
PVG-048 PVG-065 PVG-075 PVG-100 PVG-130 PVG-150 PVG-180
DRIVE Maximum (RPM) 2700 2700 2700 2400 2400 2400 2400
Minimum (RPM) 600 600 600 600 600 600 600
Torque to turn shaft (ft. lbs.) 9 9 9 24 24 40 50
Rotational Moment of Inertia (lbs.-in2) 21 21 21 50 47 150 152
OUTPUT1 Pressure (PSIA) Peak 5800 5800 4250 5800 4250 5800 5800
Continuous 5000 5000 3750 5000 3750 5000 5000
Minimum 100 100 100 100 100 100 100
Nominal Volume (GPM) at 1800 RPM and Rated Pressure For Full Displacement 21.1 28.8 33.3 42.4 57.6 63.0 78.0
CASE2 Maximum Pressure (PSI) w/ Standard Shaft Seal 25 25 25 25 25 25 25
Minimum Drain Line Hose Size #16 SAE #16 SAE #16 SAE #16 SAE #16 SAE #16 SAE #16 SAE
CONTROLS3 Minimum Pressure (PSI) Pressure Controls – Minimum Compensator Setting 200 200 200 200 200 250 250
Volume Controls (VS, VM) – Minimum Pilot Pressure 500 500 500 500 500 500 800
Maximum Pilot Pressure (PSI) Volume Control – VS 600 600 600 600 600 600 N/A
Volume Control – VM 1000 1000 1000 1000 1000 1000 1000
Stroking Rate (MSEC) at Rated Pressure, Pressure Controls (Minimum) On Stroke 40 40 40 40 40 45 45
Off Stroke 50 50 50 50 50 60 60
Volume Controls (VS, VM) On Stroke 250 250 250 250 250 250 250
Off Stroke 250 250 250 250 250 250 250
FLUID4 Viscosity (SSU) Minimum 65 65 65 65 65 65 65
Maximum 2000 2000 2000 2000 2000 2000 2000
TEMPERATURE5 Fluid Operating Range (F˜) 14 to 190 14 to 190 14 to 190 14 to 190 14 to 190 14 to 190 14 to 190
Fluid Minimum Starting (F˜) -40 -40 -40 -40 -40 -40 -40
Fluid Maximum at Case Drain Port (F˜) 230 230 230 230 230 230 230