Oilgear D-825 Legacy Variable Displacement Hydraulic Pump

Oilgear D-825 Legacy Variable Displacement Hydraulic Pump

At Rexton Hydraulic, we offer sales and repair services for the Oilgear D-825 Legacy Variable Displacement Hydraulic Pump offers precise speed control, efficient power usage, and durable performance for high-pressure industrial hydraulic systems..
 

  • Series: D Type Pumps
  • Displacement 21.36 – 802.96 cc/rev
  • Continous Pressure 1500 – 4000 psi
  • Maximum Speed 900 – 1800 RPM
  • Variable Displacements Piston Pump
  • Open Circuit Pump

Share Product:

Oilgear D-825 Legacy Variable Displacement Hydraulic Pump comes from the ever-renowned D series. This series has made a name for having the ability to withstand and resist tough and stringent applications. Coming from this series, the D-825 pump has quality features to ensure efficiency in performance. The device operates as a two-way, variable displacement pump, and it performs impressively by offering smooth and reliable hydraulic operation. This device has the capability to work at a continuous pressure rating of up to 3000 psi.

This is a legacy pump that has been made to offer unparalleled speed and flow control as demanded by processing machines that need precise and repeatable motion. This is made possible through its variable displacement capability that ensures hydraulic power is utilized only proportionally to the task accomplished. This not only enables it to eliminate energy losses and unnecessary generation of heat. This feature makes the Oilgear D-825 pump suitable for operations that demand precise control and stability.

Oilgear D-825 press design consists of a number of radial rolling piston elements that give the press a high pressure rating. The press is designed to work well with one or two control choices. It also has high-pressure relief valves to improve the safety of the press. Additionally, the press design comprises a pintle check type suction/return valve that allows the press to work well when the two-way hydraulic press is both differential and non-differential. The two-way press design allows the elimination of a large number of direction control and flow valves.

Despite being labeled as a legacy pump, the D-825 remains relevant to this day as an alternative for replacement, retrofit, and service projects requiring proven Oilgear performance. In standard applications, Oilgear recommends employing the PVV line of pumps; the D-825 remains a viable option for servicing an existing system, however.

Technical Specifications

PVG FAMILY SPECIFICATIONS

FRAME SIZE MODEL B-FRAME C-FRAME D-FRAME
PVG-048 PVG-065 PVG-075 PVG-100 PVG-130 PVG-150 PVG-180
DRIVE Maximum (RPM) 2700 2700 2700 2400 2400 2400 2400
Minimum (RPM) 600 600 600 600 600 600 600
Torque to turn shaft (ft. lbs.) 9 9 9 24 24 40 50
Rotational Moment of Inertia (lbs.-in2) 21 21 21 50 47 150 152
OUTPUT1 Pressure (PSIA) Peak 5800 5800 4250 5800 4250 5800 5800
Continuous 5000 5000 3750 5000 3750 5000 5000
Minimum 100 100 100 100 100 100 100
Nominal Volume (GPM) at 1800 RPM and Rated Pressure For Full Displacement 21.1 28.8 33.3 42.4 57.6 63.0 78.0
CASE2 Maximum Pressure (PSI) w/ Standard Shaft Seal 25 25 25 25 25 25 25
Minimum Drain Line Hose Size #16 SAE #16 SAE #16 SAE #16 SAE #16 SAE #16 SAE #16 SAE
CONTROLS3 Minimum Pressure (PSI) Pressure Controls – Minimum Compensator Setting 200 200 200 200 200 250 250
Volume Controls (VS, VM) – Minimum Pilot Pressure 500 500 500 500 500 500 800
Maximum Pilot Pressure (PSI) Volume Control – VS 600 600 600 600 600 600 N/A
Volume Control – VM 1000 1000 1000 1000 1000 1000 1000
Stroking Rate (MSEC) at Rated Pressure, Pressure Controls (Minimum) On Stroke 40 40 40 40 40 45 45
Off Stroke 50 50 50 50 50 60 60
Volume Controls (VS, VM) On Stroke 250 250 250 250 250 250 250
Off Stroke 250 250 250 250 250 250 250
FLUID4 Viscosity (SSU) Minimum 65 65 65 65 65 65 65
Maximum 2000 2000 2000 2000 2000 2000 2000
TEMPERATURE5 Fluid Operating Range (F˜) 14 to 190 14 to 190 14 to 190 14 to 190 14 to 190 14 to 190 14 to 190
Fluid Minimum Starting (F˜) -40 -40 -40 -40 -40 -40 -40
Fluid Maximum at Case Drain Port (F˜) 230 230 230 230 230 230 230