Rexton Hydraulic is a leading supplier and repair service provider of the Oilgear C-10025 Radial Rolling Piston Pump with 357.23 cc/rev displacement, 2500 psi continuous pressure, and 3000 psi peak pressure, ideal for reliable open-loop industrial hydraulic applications.
- Series: C Type Pumps
- Displacement 21.36 – 802.96 cc/rev
- Continous Pressure 1500 – 4000 psi
- Maximum Speed 900 – 1800 RPM
- Radial Piston Pump
- Open Circuit Pump
Share Product:
Oilgear C-10025 Radial Rolling Piston Pump is a constant delivery one-way hydraulic pump specifically suited to open-loop systems. It owes its heritage to the legendary 'C Series’ range of Oilgear pumps, which have been known for reliability ever since the founding of the corporation in 1921. This makes the Oilgear C-10025 an ideal choice for all those users looking for reliability and durability in the pump they use.
It has a displacement of 357.23 cc/rev, and the C-10025 provides hydraulic flow according to the size of the pumps, the pressure, and the speed of the drive shaft. It is specifically made for one-way fluid discharge. However, to reverse the discharge when needed, directional control valves can be employed.
Oilgear C-10025 pumps can operate at a rate of a maximum speed of 900 RPM and can deliver a rated continuous pressure of 2500 psi, with a rated maximum possible pressure of 3000 psi. Such a pressure capability ensures both best performance and durability in continuous as well as transient performances.
The Oilgear C Type pumps come in a range of pump sizes, providing different flows at a fixed capacity of 2500 psi and standard drive speed, enabling system designers to choose a precise setup that meets a particular requirement. The pump is flanged with an adjustable relief valve, which safeguards a hydraulic system from overload conditions. The pumps also come with a range of input shaft rotations based on installation requirements, including clockwise, counterclockwise, or reversed.
Oilgear C-10025 pumps are rubust and durable and commonly used in the operation of industry hydraulic systems, which demand reliability over the years. As Rexton Hydraulic, we supply, repair, service, and support the Oilgear C-10025 Radial Rolling Piston Pump. This ensures the appropriate selection and the right kind of servicing and support for the hydraulic pump to perform well.
Technical Specifications
PVG FAMILY SPECIFICATIONS
| FRAME SIZE MODEL | B-FRAME | C-FRAME | D-FRAME | ||||||
| PVG-048 | PVG-065 | PVG-075 | PVG-100 | PVG-130 | PVG-150 | PVG-180 | |||
| DRIVE | Maximum (RPM) | 2700 | 2700 | 2700 | 2400 | 2400 | 2400 | 2400 | |
| Minimum (RPM) | 600 | 600 | 600 | 600 | 600 | 600 | 600 | ||
| Torque to turn shaft (ft. lbs.) | 9 | 9 | 9 | 24 | 24 | 40 | 50 | ||
| Rotational Moment of Inertia (lbs.-in2) | 21 | 21 | 21 | 50 | 47 | 150 | 152 | ||
| OUTPUT1 | Pressure (PSIA) | Peak | 5800 | 5800 | 4250 | 5800 | 4250 | 5800 | 5800 |
| Continuous | 5000 | 5000 | 3750 | 5000 | 3750 | 5000 | 5000 | ||
| Minimum | 100 | 100 | 100 | 100 | 100 | 100 | 100 | ||
| Nominal Volume (GPM) at 1800 RPM and Rated Pressure For Full Displacement | 21.1 | 28.8 | 33.3 | 42.4 | 57.6 | 63.0 | 78.0 | ||
| CASE2 | Maximum Pressure (PSI) w/ Standard Shaft Seal | 25 | 25 | 25 | 25 | 25 | 25 | 25 | |
| Minimum Drain Line Hose Size | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | ||
| CONTROLS3 | Minimum Pressure (PSI) | Pressure Controls – Minimum Compensator Setting | 200 | 200 | 200 | 200 | 200 | 250 | 250 |
| Volume Controls (VS, VM) – Minimum Pilot Pressure | 500 | 500 | 500 | 500 | 500 | 500 | 800 | ||
| Maximum Pilot Pressure (PSI) | Volume Control – VS | 600 | 600 | 600 | 600 | 600 | 600 | N/A | |
| Volume Control – VM | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | ||
| Stroking Rate (MSEC) at Rated Pressure, Pressure Controls (Minimum) | On Stroke | 40 | 40 | 40 | 40 | 40 | 45 | 45 | |
| Off Stroke | 50 | 50 | 50 | 50 | 50 | 60 | 60 | ||
| Volume Controls (VS, VM) | On Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | |
| Off Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | ||
| FLUID4 | Viscosity (SSU) | Minimum | 65 | 65 | 65 | 65 | 65 | 65 | 65 |
| Maximum | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | ||
| TEMPERATURE5 | Fluid Operating Range (F˜) | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | |
| Fluid Minimum Starting (F˜) | -40 | -40 | -40 | -40 | -40 | -40 | -40 | ||
| Fluid Maximum at Case Drain Port (F˜) | 230 | 230 | 230 | 230 | 230 | 230 | 230 | ||