Oilgear DN Type 350 HP Legacy Hydraulic Pump
Oilgear DN Type 350 HP Legacy Hydraulic Pump
Rexton Hydraulic offers sales and repair services for the Oilgear DN Type 350 HP is a legacy variable displacement hydraulic pump. This is built for high-power industrial systems requiring continuous pressure, controlled flow, and long-term reliability.
- Series: D Type Pumps
- Displacement 21.36 – 802.96 cc/rev
- Continous Pressure 1500 – 4000 psi
- Maximum Speed 900 – 1800 RPM
- Variable Displacements Piston Pump
- Open Circuit Pump
Share Product:
Oilgear DN Type 350 HP Legacy Hydraulic Pump is specially designed for heavy-duty industrial applications requiring high power, sustained pressure, and accurate hydraulic control. As a heavy-duty model in the DN Series, this pump supports large machinery under continuous load conditions, hence finding its perfect application in steel processing, metal forming, heavy presses, and other high-force manufacturing systems. The DN Type 350 HP pump, with its maximum operating speed of 1200 RPM and pressure rating of up to 3500 psi continuous, provides solid and steady hydraulic performance even in the toughest surroundings.
The pump features variable displacement piston design, which adjusts the output automatically based on resistance from the system. Since only the flow required is supplied at any one time, it reduces energy consumption, limits heat generation, and increases system efficiency. It would therefore be able to provide rapid responses smoothly during changes in load, thus maintaining precision speed and pressure controls within intricate hydraulic circuits.
The Oilgear DN Type 350 HP is designed around a rugged radial rolling piston mechanism and is resistant to high torques and heavy-duty work too. The two-way hydraulic action allows it to reverse flow in a controlled manner and cuts down on the requirement for external-directed valves for flow direction. Such a design ensures that there are no complexities in piping and that it is robust to flow reversals too.
Despite the fact that the DN Type 350 HP pump qualifies as a legacy product, the pump continues to find applications in the maintenance of existing Oilgear-based systems through its known reliability and compatibility with the existing DN Series systems. Even though the PVV product line of pumps qualifies as the better option for any modern systems or major upgrades, the DN Type 350 HP qualifies as the better pump for maintaining the integrity of the existing systems.
Technical Specifications
PVG FAMILY SPECIFICATIONS
| FRAME SIZE MODEL | B-FRAME | C-FRAME | D-FRAME | ||||||
| PVG-048 | PVG-065 | PVG-075 | PVG-100 | PVG-130 | PVG-150 | PVG-180 | |||
| DRIVE | Maximum (RPM) | 2700 | 2700 | 2700 | 2400 | 2400 | 2400 | 2400 | |
| Minimum (RPM) | 600 | 600 | 600 | 600 | 600 | 600 | 600 | ||
| Torque to turn shaft (ft. lbs.) | 9 | 9 | 9 | 24 | 24 | 40 | 50 | ||
| Rotational Moment of Inertia (lbs.-in2) | 21 | 21 | 21 | 50 | 47 | 150 | 152 | ||
| OUTPUT1 | Pressure (PSIA) | Peak | 5800 | 5800 | 4250 | 5800 | 4250 | 5800 | 5800 |
| Continuous | 5000 | 5000 | 3750 | 5000 | 3750 | 5000 | 5000 | ||
| Minimum | 100 | 100 | 100 | 100 | 100 | 100 | 100 | ||
| Nominal Volume (GPM) at 1800 RPM and Rated Pressure For Full Displacement | 21.1 | 28.8 | 33.3 | 42.4 | 57.6 | 63.0 | 78.0 | ||
| CASE2 | Maximum Pressure (PSI) w/ Standard Shaft Seal | 25 | 25 | 25 | 25 | 25 | 25 | 25 | |
| Minimum Drain Line Hose Size | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | ||
| CONTROLS3 | Minimum Pressure (PSI) | Pressure Controls – Minimum Compensator Setting | 200 | 200 | 200 | 200 | 200 | 250 | 250 |
| Volume Controls (VS, VM) – Minimum Pilot Pressure | 500 | 500 | 500 | 500 | 500 | 500 | 800 | ||
| Maximum Pilot Pressure (PSI) | Volume Control – VS | 600 | 600 | 600 | 600 | 600 | 600 | N/A | |
| Volume Control – VM | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | ||
| Stroking Rate (MSEC) at Rated Pressure, Pressure Controls (Minimum) | On Stroke | 40 | 40 | 40 | 40 | 40 | 45 | 45 | |
| Off Stroke | 50 | 50 | 50 | 50 | 50 | 60 | 60 | ||
| Volume Controls (VS, VM) | On Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | |
| Off Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | ||
| FLUID4 | Viscosity (SSU) | Minimum | 65 | 65 | 65 | 65 | 65 | 65 | 65 |
| Maximum | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | ||
| TEMPERATURE5 | Fluid Operating Range (F˜) | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | |
| Fluid Minimum Starting (F˜) | -40 | -40 | -40 | -40 | -40 | -40 | -40 | ||
| Fluid Maximum at Case Drain Port (F˜) | 230 | 230 | 230 | 230 | 230 | 230 | 230 | ||