Oilgear D-2011 Legacy Variable Displacement Pump
Oilgear D-2011 Legacy Variable Displacement Pump
Rexton Hydraulic deals in sales, service, and repair solutions for the Oilgear D-2011 Legacy Variable Displacement Pump, delivering reliable support for precision industrial hydraulic applications.
- Series: D Type Pumps
- Displacement 21.36 – 802.96 cc/rev
- Continous Pressure 1500 – 4000 psi
- Maximum Speed 900 – 1800 RPM
- Variable Displacements Piston Pump
- Open Circuit Pump
Share Product:
Oilgear D-2011 Legacy Variable Displacement Pump is a proven hydraulic solution designed for applications that require accurate flow control, reliable pressure performance, and durability. Built as part of Oilgear’s legendary D Series, this pump has served industrial systems worldwide where consistent operation and smooth response are critical. Its rugged construction facilitates its reliability in demanding production conditions with stable output under varying load conditions.
Such a variable displacement pump will provide excellent speed and motion control, instantly adjusting flow to system resistance. Power consumption is directly related to work accomplished, thus serving to minimize energy losses and, therefore, the generation of unwarranted heat. Designed to avoid throttling losses, improve system efficiency, and allow smoother machine operation throughout the entire duty cycle, unlike fixed-displacement designs.
The Oilgear D-2011 comes equipped with a high-pressure radial rolling piston design and also has components related to the control and relief of the hydraulic fluid. Such a design ensures that the system does not have to rely on external flow and directional control valves. Consequently, the presence of more external components would have resulted in reduced reliability and increased maintenance costs. The fact that the D-2011 is a conventional product ensures that the equipment is still easily available through servicing, repairing, or replacing the systems.
Rexton Hydraulic offers sales, service, and repair solutions for the D-2011 Legacy Variable Displacement Pump of the Oilgear brand to supply authenticated assistance for precise industrial hydraulic systems. The D-2011 does not experience throttling losses but realizes smoother operation of the machines at a wide range of duty cycles with fast response to electric hand servos or preset position controls. You can buy and service the D-2011 Legacy Variable Displacement Pump of the Oilgear brand. Rexton Hydraulic caters to D Series sales and repair.
Technical Specifications
PVG FAMILY SPECIFICATIONS
| FRAME SIZE MODEL | B-FRAME | C-FRAME | D-FRAME | ||||||
| PVG-048 | PVG-065 | PVG-075 | PVG-100 | PVG-130 | PVG-150 | PVG-180 | |||
| DRIVE | Maximum (RPM) | 2700 | 2700 | 2700 | 2400 | 2400 | 2400 | 2400 | |
| Minimum (RPM) | 600 | 600 | 600 | 600 | 600 | 600 | 600 | ||
| Torque to turn shaft (ft. lbs.) | 9 | 9 | 9 | 24 | 24 | 40 | 50 | ||
| Rotational Moment of Inertia (lbs.-in2) | 21 | 21 | 21 | 50 | 47 | 150 | 152 | ||
| OUTPUT1 | Pressure (PSIA) | Peak | 5800 | 5800 | 4250 | 5800 | 4250 | 5800 | 5800 |
| Continuous | 5000 | 5000 | 3750 | 5000 | 3750 | 5000 | 5000 | ||
| Minimum | 100 | 100 | 100 | 100 | 100 | 100 | 100 | ||
| Nominal Volume (GPM) at 1800 RPM and Rated Pressure For Full Displacement | 21.1 | 28.8 | 33.3 | 42.4 | 57.6 | 63.0 | 78.0 | ||
| CASE2 | Maximum Pressure (PSI) w/ Standard Shaft Seal | 25 | 25 | 25 | 25 | 25 | 25 | 25 | |
| Minimum Drain Line Hose Size | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | ||
| CONTROLS3 | Minimum Pressure (PSI) | Pressure Controls – Minimum Compensator Setting | 200 | 200 | 200 | 200 | 200 | 250 | 250 |
| Volume Controls (VS, VM) – Minimum Pilot Pressure | 500 | 500 | 500 | 500 | 500 | 500 | 800 | ||
| Maximum Pilot Pressure (PSI) | Volume Control – VS | 600 | 600 | 600 | 600 | 600 | 600 | N/A | |
| Volume Control – VM | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | ||
| Stroking Rate (MSEC) at Rated Pressure, Pressure Controls (Minimum) | On Stroke | 40 | 40 | 40 | 40 | 40 | 45 | 45 | |
| Off Stroke | 50 | 50 | 50 | 50 | 50 | 60 | 60 | ||
| Volume Controls (VS, VM) | On Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | |
| Off Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | ||
| FLUID4 | Viscosity (SSU) | Minimum | 65 | 65 | 65 | 65 | 65 | 65 | 65 |
| Maximum | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | ||
| TEMPERATURE5 | Fluid Operating Range (F˜) | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | |
| Fluid Minimum Starting (F˜) | -40 | -40 | -40 | -40 | -40 | -40 | -40 | ||
| Fluid Maximum at Case Drain Port (F˜) | 230 | 230 | 230 | 230 | 230 | 230 | 230 | ||