Rexton Hydraulic deals in sales and services of the Oilgear PVM-075 Variable Displacement Axial Piston Pump, offering 75 cc/rev displacement, 260 bar continuous pressure and up to ~118.5 L/min flow.
- Series: PVM Legacy Pumps
- Displacement 11 – 130 cc/rev
- Continuous Pressure 206 Bar
- Maximum Speed 2400 – 3600 RPM
- Variable Displacement Pump
- Open Circuit Pump
Share Product:
Oilgear PVM-075 Variable Displacement Axial Piston Hydraulic Pump is engineered for hydraulic systems that require flexible flow control, strong mid-range power delivery, and long service life. Part of Oilgear's respected PVM legacy series, this pump provides consistent performance in industrial and mobile applications where precision, reliability, and durability are key.
With a displacement of 75 cc/rev (≈ 4.61 in³/rev), the PVM-075 can produce high hydraulic flow per shaft revolution, ideal for medium- to high-flow circuits. Rated at 1800 RPM and rated continuous pressure, the pump produces approximately 118.5 litres per minute (≈ 31.3 gpm), allowing for larger actuators, power units, auxiliary hydraulics and more demanding fluid-power systems.
Its design targets open-loop hydraulic circuits, making the integration of the system easier and it can, therefore, be installed for various installations ranging from industrial machinery to mobile hydraulic platforms. It supports a maximum continuous pressure of 260 bar (≈ 3750 psi) and a maximum speed of 2700 RPM.
Oilgear designs the PVM series for rugged reliability and a long working life. The internal rotating group and piston assembly are of hardened materials and machined to close tolerances to minimize wear and enhance resistance to contamination. A balanced swashplate design contributes to smooth, efficient hydraulic delivery, even in applications with newer low-lubricity hydraulic fluids. These features help ensure consistent flow and pressure delivery with minimal performance loss over time.
PVM-075 is a variable-displacement pump that provides systems designers with the ability to vary flow output in response to load demand. Such pumps improve energy efficiency and reduce heat generation compared to fixed-displacement pumps. This dramatically increases control accuracy. Thus, installed in power units, compact hydraulic presses, material handling systems and mobile equipment, the pump can adapt to each changing demand while always providing steady performance.
At Rexton Hydraulic, we supply, install, and support the full Oilgear PVM pump range-including the PVM-075. We help with correct model selection, professional installation and long-term maintenance so your hydraulic systems deliver reliable, efficient performance over many years of operation.
Technical Specifications
PVG FAMILY SPECIFICATIONS
| FRAME SIZE MODEL | B-FRAME | C-FRAME | D-FRAME | ||||||
| PVG-048 | PVG-065 | PVG-075 | PVG-100 | PVG-130 | PVG-150 | PVG-180 | |||
| DRIVE | Maximum (RPM) | 2700 | 2700 | 2700 | 2400 | 2400 | 2400 | 2400 | |
| Minimum (RPM) | 600 | 600 | 600 | 600 | 600 | 600 | 600 | ||
| Torque to turn shaft (ft. lbs.) | 9 | 9 | 9 | 24 | 24 | 40 | 50 | ||
| Rotational Moment of Inertia (lbs.-in2) | 21 | 21 | 21 | 50 | 47 | 150 | 152 | ||
| OUTPUT1 | Pressure (PSIA) | Peak | 5800 | 5800 | 4250 | 5800 | 4250 | 5800 | 5800 |
| Continuous | 5000 | 5000 | 3750 | 5000 | 3750 | 5000 | 5000 | ||
| Minimum | 100 | 100 | 100 | 100 | 100 | 100 | 100 | ||
| Nominal Volume (GPM) at 1800 RPM and Rated Pressure For Full Displacement | 21.1 | 28.8 | 33.3 | 42.4 | 57.6 | 63.0 | 78.0 | ||
| CASE2 | Maximum Pressure (PSI) w/ Standard Shaft Seal | 25 | 25 | 25 | 25 | 25 | 25 | 25 | |
| Minimum Drain Line Hose Size | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | ||
| CONTROLS3 | Minimum Pressure (PSI) | Pressure Controls – Minimum Compensator Setting | 200 | 200 | 200 | 200 | 200 | 250 | 250 |
| Volume Controls (VS, VM) – Minimum Pilot Pressure | 500 | 500 | 500 | 500 | 500 | 500 | 800 | ||
| Maximum Pilot Pressure (PSI) | Volume Control – VS | 600 | 600 | 600 | 600 | 600 | 600 | N/A | |
| Volume Control – VM | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | ||
| Stroking Rate (MSEC) at Rated Pressure, Pressure Controls (Minimum) | On Stroke | 40 | 40 | 40 | 40 | 40 | 45 | 45 | |
| Off Stroke | 50 | 50 | 50 | 50 | 50 | 60 | 60 | ||
| Volume Controls (VS, VM) | On Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | |
| Off Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | ||
| FLUID4 | Viscosity (SSU) | Minimum | 65 | 65 | 65 | 65 | 65 | 65 | 65 |
| Maximum | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | ||
| TEMPERATURE5 | Fluid Operating Range (F˜) | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | |
| Fluid Minimum Starting (F˜) | -40 | -40 | -40 | -40 | -40 | -40 | -40 | ||
| Fluid Maximum at Case Drain Port (F˜) | 230 | 230 | 230 | 230 | 230 | 230 | 230 | ||