PFCM-100 Fixed Displacement Piston Pump
PFCM-100 Fixed Displacement Piston Pump
Rexton Hydraulic deals in sales and repair services for the Oilgear PFCM-100 Fixed Displacement Axial Piston Pump, engineered for high-pressure hydraulic systems needing consistent flow, 1000 bar capacity and robust long-term performance.
- Series: PFCM Pump
- Displacement 69.8 ml/rev – 136.7 ml/rev
- Nominal Pressure 415 Bar
- Maximum Pressure 1000 Bar
- Maximum Speed 2400 RPM
- Fixed Displacement Pump
- Open Circuit Pump
Share Product:
The Oilgear PFCM-100 is a fixed-displacement axial piston pump designed for high-pressure, heavy-duty hydraulic systems. It provides a fixed and reliable flow per shaft revolution, ideal for configurations requiring stable output, repeatability, and robustness.
Constructed on the proven PFCM series platform, the PFCM-100 resists extreme pressure loads up to 1000 bar ≈ 14,500 psi, enabling its reliable performance in the most demanding hydraulic applications, such as hydraulic presses, intensifier units, test rigs, extrusion or forging machines, marine hydraulic systems, and special industrial installations.
This pump features a stationary-piston block and hardened internal components, which are designed for very long service life and heavy workload resistance. The robust construction reduces internal wear and improves contamination tolerance even when used with low-viscosity or modern hydraulic fluids. The PFCM-100 will support both standard oils and advanced fluid types, giving flexibility in hydraulic system design.
The hydrodynamic thrust bearing with forced lubrication on the internal architecture of the pump takes care of the thrust loads. This design keeps rotation stable and smooth, thus allowing operation under severe conditions with minimum maintenance.
Due to its fixed-displacement nature, the PFCM-100 delivers consistent, predictable flow and hydraulic pressure: a perfect fit for operations where high accuracy, repeatability, and smooth performance are absolutely required. This makes it suitable for heavy-duty industrial applications because any form of unpredictability is just not acceptable.
With its high-pressure rating and robust build, the PFCM-100 remains versatile enough for integration, whether in new hydraulic systems or existing setups that need upgrading. Its balanced design minimizes downtime and ensures dependable operation for many years of continuous service.
At Rexton Hydraulic, we can supply, install, service, and maintain the PFCM-100 pump. We support proper model selection, installation guidance, and long-term maintenance to ensure that your hydraulic setup provides consistent, high-pressure performance.
Technical Specifications
PVG FAMILY SPECIFICATIONS
| FRAME SIZE MODEL | B-FRAME | C-FRAME | D-FRAME | ||||||
| PVG-048 | PVG-065 | PVG-075 | PVG-100 | PVG-130 | PVG-150 | PVG-180 | |||
| DRIVE | Maximum (RPM) | 2700 | 2700 | 2700 | 2400 | 2400 | 2400 | 2400 | |
| Minimum (RPM) | 600 | 600 | 600 | 600 | 600 | 600 | 600 | ||
| Torque to turn shaft (ft. lbs.) | 9 | 9 | 9 | 24 | 24 | 40 | 50 | ||
| Rotational Moment of Inertia (lbs.-in2) | 21 | 21 | 21 | 50 | 47 | 150 | 152 | ||
| OUTPUT1 | Pressure (PSIA) | Peak | 5800 | 5800 | 4250 | 5800 | 4250 | 5800 | 5800 |
| Continuous | 5000 | 5000 | 3750 | 5000 | 3750 | 5000 | 5000 | ||
| Minimum | 100 | 100 | 100 | 100 | 100 | 100 | 100 | ||
| Nominal Volume (GPM) at 1800 RPM and Rated Pressure For Full Displacement | 21.1 | 28.8 | 33.3 | 42.4 | 57.6 | 63.0 | 78.0 | ||
| CASE2 | Maximum Pressure (PSI) w/ Standard Shaft Seal | 25 | 25 | 25 | 25 | 25 | 25 | 25 | |
| Minimum Drain Line Hose Size | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | ||
| CONTROLS3 | Minimum Pressure (PSI) | Pressure Controls – Minimum Compensator Setting | 200 | 200 | 200 | 200 | 200 | 250 | 250 |
| Volume Controls (VS, VM) – Minimum Pilot Pressure | 500 | 500 | 500 | 500 | 500 | 500 | 800 | ||
| Maximum Pilot Pressure (PSI) | Volume Control – VS | 600 | 600 | 600 | 600 | 600 | 600 | N/A | |
| Volume Control – VM | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | ||
| Stroking Rate (MSEC) at Rated Pressure, Pressure Controls (Minimum) | On Stroke | 40 | 40 | 40 | 40 | 40 | 45 | 45 | |
| Off Stroke | 50 | 50 | 50 | 50 | 50 | 60 | 60 | ||
| Volume Controls (VS, VM) | On Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | |
| Off Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | ||
| FLUID4 | Viscosity (SSU) | Minimum | 65 | 65 | 65 | 65 | 65 | 65 | 65 |
| Maximum | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | ||
| TEMPERATURE5 | Fluid Operating Range (F˜) | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | |
| Fluid Minimum Starting (F˜) | -40 | -40 | -40 | -40 | -40 | -40 | -40 | ||
| Fluid Maximum at Case Drain Port (F˜) | 230 | 230 | 230 | 230 | 230 | 230 | 230 | ||