PVG-065 Variable Displacement Axial Piston Pump
PVG-065 Variable Displacement Axial Piston Pump
- Series: PVG Pump
- Displacement 50 – 99 cc/rev
- Nominal Pressure 300 Bar
- Maximum Pressure 400 Bar
- Maximum Speed 2000 – 3000 RPM
- High-Pressure Pump
- Open Circuit Pump
Share Product:
PVG-065 Variable Displacement Axial Piston Pump
The PVG-065 Variable Displacement Axial Piston Pump is designed to deliver high performance, durability, and efficiency in demanding hydraulic systems. This pump provides precise control of flow and pressure, making it ideal for industrial, mobile, and construction machinery applications. With its compact design and reliable build, it ensures long-lasting operation even under continuous heavy-duty use.
The pump operates on the axial piston principle, where the displacement can be adjusted as per the system’s requirement. This flexibility helps in reducing energy loss and improving overall efficiency. The PVG-065 Variable Displacement Axial Piston Pump allows smooth and responsive control, ensuring optimal hydraulic performance in all working conditions. It has been engineered to handle high operating pressures with low noise levels, making it a preferred choice for modern hydraulic systems.
The body of the pump is made from high-strength materials to resist wear and corrosion. Precision manufacturing and strict quality control ensure consistent performance. The internal components are designed to minimize friction, resulting in improved efficiency and a longer service life.
The PVG-065 Variable Axial Piston Pump delivers outstanding performance and precision in every operation. It is specially designed for hydraulic systems that demand reliability, energy efficiency, and smooth flow control. This pump offers variable displacement, allowing the user to adjust flow according to the system’s requirements
In many industries, the PVG-065 pump is used for applications that demand reliability and variable flow control. It is commonly installed in injection molding machines, presses, cranes, and marine systems. Regular maintenance is minimal due to its advanced design and self-lubricating features.
The PVG-065 Hydraulic Axial Piston Pump has been trusted by professionals worldwide. Its robust design and adjustable displacement make it suitable for both high-speed and low-speed operations. Whether used for power transmission or motion control, this pump consistently delivers the performance and reliability that industries depend on.
Technical Specifications
NOMINAL DIMENSIONS
| Frame Size |
Length | Width | Height | Weight | Face Mounting | ||||
| in. | mm | in. | mm | in. | mm | lbs | kg | ||
| B | 12.0 | 303,9 | 6.9 | 174,5 | 6.3 | 160,4 | 68 | 31 | SAE “B” 2 & 4 Bolt |
NOMINAL OPERATING PARAMETERS
| Theoretical Maximum Displacement | in^3/rev | 3.98 |
| ml/rev | 65,0 | |
| Rated Continuous Pressure | psi | 5000 |
| bar | 344,8 | |
| Peak Pressure | psi | 5800 |
| bar | 400,0 | |
| Flow Rate at 1800 RPM, rated continuous pressure & 14.7 psi (1.01 bar abs) inlet conditions | gpm | 28.8 |
| l/min | 108,9 | |
| Maximum Speed | rpm | 2700 |
| Power Input at rated continuous pressure & 1800 rpm | hp | 100 |
| kW | 74,6 |
Technical Specifications
PVG FAMILY SPECIFICATIONS
| FRAME SIZE MODEL | B-FRAME | C-FRAME | D-FRAME | ||||||
| PVG-048 | PVG-065 | PVG-075 | PVG-100 | PVG-130 | PVG-150 | PVG-180 | |||
| DRIVE | Maximum (RPM) | 2700 | 2700 | 2700 | 2400 | 2400 | 2400 | 2400 | |
| Minimum (RPM) | 600 | 600 | 600 | 600 | 600 | 600 | 600 | ||
| Torque to turn shaft (ft. lbs.) | 9 | 9 | 9 | 24 | 24 | 40 | 50 | ||
| Rotational Moment of Inertia (lbs.-in2) | 21 | 21 | 21 | 50 | 47 | 150 | 152 | ||
| OUTPUT1 | Pressure (PSIA) | Peak | 5800 | 5800 | 4250 | 5800 | 4250 | 5800 | 5800 |
| Continuous | 5000 | 5000 | 3750 | 5000 | 3750 | 5000 | 5000 | ||
| Minimum | 100 | 100 | 100 | 100 | 100 | 100 | 100 | ||
| Nominal Volume (GPM) at 1800 RPM and Rated Pressure For Full Displacement | 21.1 | 28.8 | 33.3 | 42.4 | 57.6 | 63.0 | 78.0 | ||
| CASE2 | Maximum Pressure (PSI) w/ Standard Shaft Seal | 25 | 25 | 25 | 25 | 25 | 25 | 25 | |
| Minimum Drain Line Hose Size | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | ||
| CONTROLS3 | Minimum Pressure (PSI) | Pressure Controls – Minimum Compensator Setting | 200 | 200 | 200 | 200 | 200 | 250 | 250 |
| Volume Controls (VS, VM) – Minimum Pilot Pressure | 500 | 500 | 500 | 500 | 500 | 500 | 800 | ||
| Maximum Pilot Pressure (PSI) | Volume Control – VS | 600 | 600 | 600 | 600 | 600 | 600 | N/A | |
| Volume Control – VM | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | ||
| Stroking Rate (MSEC) at Rated Pressure, Pressure Controls (Minimum) | On Stroke | 40 | 40 | 40 | 40 | 40 | 45 | 45 | |
| Off Stroke | 50 | 50 | 50 | 50 | 50 | 60 | 60 | ||
| Volume Controls (VS, VM) | On Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | |
| Off Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | ||
| FLUID4 | Viscosity (SSU) | Minimum | 65 | 65 | 65 | 65 | 65 | 65 | 65 |
| Maximum | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | ||
| TEMPERATURE5 | Fluid Operating Range (F˜) | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | |
| Fluid Minimum Starting (F˜) | -40 | -40 | -40 | -40 | -40 | -40 | -40 | ||
| Fluid Maximum at Case Drain Port (F˜) | 230 | 230 | 230 | 230 | 230 | 230 | 230 | ||