Oilgear PVWC-022 Axial Piston Hydraulic Pump
Oilgear PVWC-022 Axial Piston Hydraulic Pump
Rexton Hydraulic offers the Oilgear PVWC-022 Variable Displacement Axial Piston Pump, featuring 22.1 ml/rev displacement, 207 bar continuous pressure and 32.2 l/min flow at 1800 RPM for closed-loop hydraulic systems.
- Series: PVWC Legacy Pumps
- Displacement 11 – 22 cc/rev
- Continous Pressure 207 – 275 Bar
- Maximum Speed 3600 RPM
- Variable Displacement Pump
- Closed Circuit Pump
Share Product:
Oilgear PVWC-022 Variable Displacement Axial Piston Hydraulic Pump is designed specifically for closed hydraulic systems, where fine control, high efficiency, and reliable pressure management are required. Built into Oilgear's PVWC Series, this pump is intended for operation under conditions involving hydraulic or low-lubricity fluid mediums.
With a maximum theoretical displacement of 22.1 ml/rev, the PVWC-022 is capable of accurate flow delivery and responds dynamically to changing system conditions. Variable displacement technology also makes the pump effective in controlling output, thus reducing energy loss, heat generation, and maintaining a stable system performance. This is especially true when dealing with closed-loop systems where accurate flow control directly affects machine response.
It has a continuous pressure rating of 207 bar, guaranteeing reliable performance even during long cycles. In the case of peak pressures in load spikes with a 10% duty cycle, the motor is capable of handling 240 bar peak pressure and has a maximum peak pressure rating of 350 bar. At a speed of up to 3600 RPM, the PVWC-022 has a maximum flow rate of 8.5 gpm (32.2 l/min) at 1800 RPM.
In terms of dimensions, the PVWC-022 can be provided both with and without a charge pump, depending on system design needs. The portable design and side ports of this pump make it easy to install in a space-constrained hydraulic system and at the same time easy to access for maintenance. The rotating group inside the pump is designed using hard-edged elements, which provide improved durability despite the high-pressure continuity.
Common applications for the Oilgear PVWC-022 series hydraulic motor include hydrostatic drive systems, industrial machinery, material handling systems, mobile hydraulic systems, and closed loop power transmission systems. As Rexton Hydraulic, we also sell, service, repair, and support the use of the Oilgear PVWC-022 hydraulic pumps to guarantee proper setup, proper technical consultation and proper long-term functionality of the hydraulic system.
Technical Specifications
PVG FAMILY SPECIFICATIONS
| FRAME SIZE MODEL | B-FRAME | C-FRAME | D-FRAME | ||||||
| PVG-048 | PVG-065 | PVG-075 | PVG-100 | PVG-130 | PVG-150 | PVG-180 | |||
| DRIVE | Maximum (RPM) | 2700 | 2700 | 2700 | 2400 | 2400 | 2400 | 2400 | |
| Minimum (RPM) | 600 | 600 | 600 | 600 | 600 | 600 | 600 | ||
| Torque to turn shaft (ft. lbs.) | 9 | 9 | 9 | 24 | 24 | 40 | 50 | ||
| Rotational Moment of Inertia (lbs.-in2) | 21 | 21 | 21 | 50 | 47 | 150 | 152 | ||
| OUTPUT1 | Pressure (PSIA) | Peak | 5800 | 5800 | 4250 | 5800 | 4250 | 5800 | 5800 |
| Continuous | 5000 | 5000 | 3750 | 5000 | 3750 | 5000 | 5000 | ||
| Minimum | 100 | 100 | 100 | 100 | 100 | 100 | 100 | ||
| Nominal Volume (GPM) at 1800 RPM and Rated Pressure For Full Displacement | 21.1 | 28.8 | 33.3 | 42.4 | 57.6 | 63.0 | 78.0 | ||
| CASE2 | Maximum Pressure (PSI) w/ Standard Shaft Seal | 25 | 25 | 25 | 25 | 25 | 25 | 25 | |
| Minimum Drain Line Hose Size | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | ||
| CONTROLS3 | Minimum Pressure (PSI) | Pressure Controls – Minimum Compensator Setting | 200 | 200 | 200 | 200 | 200 | 250 | 250 |
| Volume Controls (VS, VM) – Minimum Pilot Pressure | 500 | 500 | 500 | 500 | 500 | 500 | 800 | ||
| Maximum Pilot Pressure (PSI) | Volume Control – VS | 600 | 600 | 600 | 600 | 600 | 600 | N/A | |
| Volume Control – VM | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | ||
| Stroking Rate (MSEC) at Rated Pressure, Pressure Controls (Minimum) | On Stroke | 40 | 40 | 40 | 40 | 40 | 45 | 45 | |
| Off Stroke | 50 | 50 | 50 | 50 | 50 | 60 | 60 | ||
| Volume Controls (VS, VM) | On Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | |
| Off Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | ||
| FLUID4 | Viscosity (SSU) | Minimum | 65 | 65 | 65 | 65 | 65 | 65 | 65 |
| Maximum | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | ||
| TEMPERATURE5 | Fluid Operating Range (F˜) | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | |
| Fluid Minimum Starting (F˜) | -40 | -40 | -40 | -40 | -40 | -40 | -40 | ||
| Fluid Maximum at Case Drain Port (F˜) | 230 | 230 | 230 | 230 | 230 | 230 | 230 | ||