Rexton Hydraulic is a leading supplier and repair service provider of the Oilgear PVM-076 Variable Displacement Axial Piston Pump. These comes with 76 cc/rev displacement, adjustable flow control and reliable performance for medium- to heavy-duty hydraulic systems.
- Series: PVM Legacy Pumps
- Displacement 11 – 130 cc/rev
- Continuous Pressure 206 Bar
- Maximum Speed 2400 – 3600 RPM
- Variable Displacement Pump
- Open Circuit Pump
Share Product:
Oilgear PVM-076 Variable Displacement Axial Piston Hydraulic Pump is a rugged, high-performance solution in the PVM series for open-loop hydraulic systems requiring adjustable flow, smooth response, and a long service life. Part of the Oilgear PVM family of legacy products, the PVM-076 is distinguished by versatile operation and a modular, efficient design enabling integrators, OEMs, and system builders to meet real-world performance challenges.
It offers up to 76 cc/rev and accordingly high hydraulic fluid output per revolution; the PVM-076 has quite extensive application in medium and heavy-duty hydraulic systems. The variable displacement control of this pump allows the pump to adjust the flow output depending on system demand, which improves efficiency, reduces heat generation, and helps systems to respond dynamically to changes in load.
This pump is designed for open-loop circuits, allowing for much simpler system design and integration. With this setup, performance is consistent over a wide operating range, including industrial machinery, mobile equipment, auxiliary hydraulic circuits, and power units. Due to its variable output, the PVM-076 is particularly helpful in applications featuring fluctuating flow demands, such as multi-function hydraulic actuators or variable loading conditions.
Oilgear designed the PVM series for durability and long life. The PVM-076 features hardened internals, precision machining, and a balanced rotating group for smooth hydraulic delivery and reduced wear over long duty cycles. Internal construction also allows the use of a wide range of modern hydraulic fluids, from low-viscosity to specialty fluid formulations, further enhancing adaptability in a wide field of industrial applications.
Typical applications for the pump include material handling systems, medium-duty presses, mobile construction hydraulics, servo control circuits, and auxiliary power units for which high efficiency and performance is important. The pump's modular design also makes service, maintenance, and retrofit installation more easily accomplished.
We at Rexton Hydraulic supply, install, and service the complete lineup of Oilgear PVM pumps, including the PVM-076. From model selection through professional installation support to long-term maintenance, let our technical team ensure that your hydraulic systems perform with continued efficiency.
Technical Specifications
PVG FAMILY SPECIFICATIONS
| FRAME SIZE MODEL | B-FRAME | C-FRAME | D-FRAME | ||||||
| PVG-048 | PVG-065 | PVG-075 | PVG-100 | PVG-130 | PVG-150 | PVG-180 | |||
| DRIVE | Maximum (RPM) | 2700 | 2700 | 2700 | 2400 | 2400 | 2400 | 2400 | |
| Minimum (RPM) | 600 | 600 | 600 | 600 | 600 | 600 | 600 | ||
| Torque to turn shaft (ft. lbs.) | 9 | 9 | 9 | 24 | 24 | 40 | 50 | ||
| Rotational Moment of Inertia (lbs.-in2) | 21 | 21 | 21 | 50 | 47 | 150 | 152 | ||
| OUTPUT1 | Pressure (PSIA) | Peak | 5800 | 5800 | 4250 | 5800 | 4250 | 5800 | 5800 |
| Continuous | 5000 | 5000 | 3750 | 5000 | 3750 | 5000 | 5000 | ||
| Minimum | 100 | 100 | 100 | 100 | 100 | 100 | 100 | ||
| Nominal Volume (GPM) at 1800 RPM and Rated Pressure For Full Displacement | 21.1 | 28.8 | 33.3 | 42.4 | 57.6 | 63.0 | 78.0 | ||
| CASE2 | Maximum Pressure (PSI) w/ Standard Shaft Seal | 25 | 25 | 25 | 25 | 25 | 25 | 25 | |
| Minimum Drain Line Hose Size | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | ||
| CONTROLS3 | Minimum Pressure (PSI) | Pressure Controls – Minimum Compensator Setting | 200 | 200 | 200 | 200 | 200 | 250 | 250 |
| Volume Controls (VS, VM) – Minimum Pilot Pressure | 500 | 500 | 500 | 500 | 500 | 500 | 800 | ||
| Maximum Pilot Pressure (PSI) | Volume Control – VS | 600 | 600 | 600 | 600 | 600 | 600 | N/A | |
| Volume Control – VM | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | ||
| Stroking Rate (MSEC) at Rated Pressure, Pressure Controls (Minimum) | On Stroke | 40 | 40 | 40 | 40 | 40 | 45 | 45 | |
| Off Stroke | 50 | 50 | 50 | 50 | 50 | 60 | 60 | ||
| Volume Controls (VS, VM) | On Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | |
| Off Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | ||
| FLUID4 | Viscosity (SSU) | Minimum | 65 | 65 | 65 | 65 | 65 | 65 | 65 |
| Maximum | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | ||
| TEMPERATURE5 | Fluid Operating Range (F˜) | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | |
| Fluid Minimum Starting (F˜) | -40 | -40 | -40 | -40 | -40 | -40 | -40 | ||