  • Series: D Type Pumps
  • Displacement 21.36 – 802.96 cc/rev
  • Continous Pressure 1500 – 4000 psi
  • Maximum Speed 900 – 1800 RPM
  • Variable Displacements Piston Pump
  • Open Circuit Pump

Share Product:

Oilgear D-811 Legacy Variable Displacement Hydraulic Pump is an established product in applications that require consistent performance, precise speed control, and reliable operation in continuous industrial service. The two-way variable pump is part of the Oilgear D Series and has earned its reputation as a reliable workhorse in processing machines and heavy-duty hydraulic systems over many years of service. The heavy-duty nature of the pump and its proven designs make it suitable for operating in environments that require stability and precision in operations.

The legacy pump features an open-loop hydraulic circuit, and it reacts instantly to either electric hand servos or fixed speed position controls. This fast-acting feature enables perfect flow transitions and speed regulation, as well as controlled pressure, without consuming surplus power. The variable displacement action also guarantees the use of power whenever it is needed, hence fewer heats are produced in the system, resulting in an efficient process. The pump adjusts accordingly whenever changes occur in the fluid resistance within the system to ensure constant performance without throttling and flow restrictions.

Oilgear D-811 features a positive variable delivery radial rolling piston design. It is able to handle high pressure yet still have long-lasting components. The design of the pump is engineered to reduce internal stresses. It is therefore able to work adequately even under long cycle times. The design of the pump eliminates the need to use a multitude of directional valves to control flow. Such aspects help reduce the complexities associated with the setup. Piping is also reduced.

In real-life applications, the D-811 Legacy Pump features smooth reversal and the ability to vary the flow infinitely. This capability helps to ensure accuracy-based applications. Even though Oilgear has developed newer PVV pumps for newer applications, the D-811 Legacy Pump remains a reliable model for upgrading applications where consistency and compatibility are necessary. This model helps to ensure steady hydraulic power.

Technical Specifications

PVG FAMILY SPECIFICATIONS

FRAME SIZE MODEL B-FRAME C-FRAME D-FRAME
PVG-048 PVG-065 PVG-075 PVG-100 PVG-130 PVG-150 PVG-180
DRIVE Maximum (RPM) 2700 2700 2700 2400 2400 2400 2400
Minimum (RPM) 600 600 600 600 600 600 600
Torque to turn shaft (ft. lbs.) 9 9 9 24 24 40 50
Rotational Moment of Inertia (lbs.-in2) 21 21 21 50 47 150 152
OUTPUT1 Pressure (PSIA) Peak 5800 5800 4250 5800 4250 5800 5800
Continuous 5000 5000 3750 5000 3750 5000 5000
Minimum 100 100 100 100 100 100 100
Nominal Volume (GPM) at 1800 RPM and Rated Pressure For Full Displacement 21.1 28.8 33.3 42.4 57.6 63.0 78.0
CASE2 Maximum Pressure (PSI) w/ Standard Shaft Seal 25 25 25 25 25 25 25
Minimum Drain Line Hose Size #16 SAE #16 SAE #16 SAE #16 SAE #16 SAE #16 SAE #16 SAE
CONTROLS3 Minimum Pressure (PSI) Pressure Controls – Minimum Compensator Setting 200 200 200 200 200 250 250
Volume Controls (VS, VM) – Minimum Pilot Pressure 500 500 500 500 500 500 800
Maximum Pilot Pressure (PSI) Volume Control – VS 600 600 600 600 600 600 N/A
Volume Control – VM 1000 1000 1000 1000 1000 1000 1000
Stroking Rate (MSEC) at Rated Pressure, Pressure Controls (Minimum) On Stroke 40 40 40 40 40 45 45
Off Stroke 50 50 50 50 50 60 60
Volume Controls (VS, VM) On Stroke 250 250 250 250 250 250 250
Off Stroke 250 250 250 250 250 250 250
FLUID4 Viscosity (SSU) Minimum 65 65 65 65 65 65 65
Maximum 2000 2000 2000 2000 2000 2000 2000
TEMPERATURE5 Fluid Operating Range (F˜) 14 to 190 14 to 190 14 to 190 14 to 190 14 to 190 14 to 190 14 to 190
Fluid Minimum Starting (F˜) -40 -40 -40 -40 -40 -40 -40
Fluid Maximum at Case Drain Port (F˜) 230 230 230 230 230 230 230