Oilgear D-6017 Legacy Variable Displacement Hydraulic Pump
Oilgear D-6017 Legacy Variable Displacement Hydraulic Pump
Rexton Hydraulic deals in sales and repair services for the Oilgear D-6017 Legacy Variable Displacement Hydraulic Pump, offering reliable solutions for industrial hydraulic systems requiring precise flow and pressure control.
- Series: D Type Pumps
- Displacement 21.36 – 802.96 cc/rev
- Continous Pressure 1500 – 4000 psi
- Maximum Speed 900 – 1800 RPM
- Variable Displacements Piston Pump
- Open Circuit Pump
Share Product:
Oilgear D-6017 Legacy Variable Displacement Hydraulic Pump is a heavy-duty two-way variable pump known for precise control over speed and flow rate in high-end applications. The D-6017 is part of Oilgear’s legendary line of D Series products and has been developed for continuous usage in harsh production environments.
The D-6017 is equipped with a positive and variable delivery design that utilizes a variety of radial pistons to ensure a smooth flow of fluid. The design ensures that the fluid pump responds to the load instantaneously to maintain a consistent pressure and flow. The power consumption of the fluid pump is also directly related to the work that the fluid pump does to avoid the generation of heat.
The D-6017 Pump is particularly suited for open loop hydraulic systems that demand precise speed regulation controls as well as bidirectional flow. It immediately responds to electric hand servos or fixed speed position controls, which makes it suitable for processing machines, presses, machine tools, as well as specialized industrial machines. Since it does not require multiple directional or flow control valves, its circuits are quite simplified when compared to other pumps.
With its maximum displacement of 328.56 cc/rev, Oilgear D-6017 provides high flow rates and control. It is capable of operating at a maximum of 2100 psi in a continuous manner. This aspect of Oilgear D-6017 makes it ideal for applications that require medium or high pressure and ensure its reliability in terms of performance. Further, its design enables it to have a longer life.
Although Oil gear advises the migration of the legacy range of the D Series to the new range of the PVV series of pumps, the D-6017 continued to be deployed in existing stations mainly because the company provided regular replacement services.
Technical Specifications
PVG FAMILY SPECIFICATIONS
| FRAME SIZE MODEL | B-FRAME | C-FRAME | D-FRAME | ||||||
| PVG-048 | PVG-065 | PVG-075 | PVG-100 | PVG-130 | PVG-150 | PVG-180 | |||
| DRIVE | Maximum (RPM) | 2700 | 2700 | 2700 | 2400 | 2400 | 2400 | 2400 | |
| Minimum (RPM) | 600 | 600 | 600 | 600 | 600 | 600 | 600 | ||
| Torque to turn shaft (ft. lbs.) | 9 | 9 | 9 | 24 | 24 | 40 | 50 | ||
| Rotational Moment of Inertia (lbs.-in2) | 21 | 21 | 21 | 50 | 47 | 150 | 152 | ||
| OUTPUT1 | Pressure (PSIA) | Peak | 5800 | 5800 | 4250 | 5800 | 4250 | 5800 | 5800 |
| Continuous | 5000 | 5000 | 3750 | 5000 | 3750 | 5000 | 5000 | ||
| Minimum | 100 | 100 | 100 | 100 | 100 | 100 | 100 | ||
| Nominal Volume (GPM) at 1800 RPM and Rated Pressure For Full Displacement | 21.1 | 28.8 | 33.3 | 42.4 | 57.6 | 63.0 | 78.0 | ||
| CASE2 | Maximum Pressure (PSI) w/ Standard Shaft Seal | 25 | 25 | 25 | 25 | 25 | 25 | 25 | |
| Minimum Drain Line Hose Size | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | ||
| CONTROLS3 | Minimum Pressure (PSI) | Pressure Controls – Minimum Compensator Setting | 200 | 200 | 200 | 200 | 200 | 250 | 250 |
| Volume Controls (VS, VM) – Minimum Pilot Pressure | 500 | 500 | 500 | 500 | 500 | 500 | 800 | ||
| Maximum Pilot Pressure (PSI) | Volume Control – VS | 600 | 600 | 600 | 600 | 600 | 600 | N/A | |
| Volume Control – VM | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | ||
| Stroking Rate (MSEC) at Rated Pressure, Pressure Controls (Minimum) | On Stroke | 40 | 40 | 40 | 40 | 40 | 45 | 45 | |
| Off Stroke | 50 | 50 | 50 | 50 | 50 | 60 | 60 | ||
| Volume Controls (VS, VM) | On Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | |
| Off Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | ||
| FLUID4 | Viscosity (SSU) | Minimum | 65 | 65 | 65 | 65 | 65 | 65 | 65 |
| Maximum | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | ||
| TEMPERATURE5 | Fluid Operating Range (F˜) | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | |
| Fluid Minimum Starting (F˜) | -40 | -40 | -40 | -40 | -40 | -40 | -40 | ||
| Fluid Maximum at Case Drain Port (F˜) | 230 | 230 | 230 | 230 | 230 | 230 | 230 | ||