Oilgear D-1217 Legacy Variable Displacement Pump

Oilgear D-1217 Legacy Variable Displacement Pump

Rexton Hydraulic prove sales, repair and replacement support for the Oilgear D-1217 Legacy Variable Displacement Pump. This is a legacy model, but it remains widely used in existing installations where reliable performance is essential.
 

  • Series: D Type Pumps
  • Displacement 21.36 – 802.96 cc/rev
  • Continous Pressure 1500 – 4000 psi
  • Maximum Speed 900 – 1800 RPM
  • Variable Displacements Piston Pump
  • Open Circuit Pump

Share Product:

D-1217 Legacy Variable Displacement Pump is known for power, reliability and durability. This two-way variable displacement hydraulic pump is tested and proven to perform well under continuous usage conditions over the years in processing machines, manufacturing facilities, and heavy-duty hydraulic systems. Its ruggedness and flow control capabilities make it the most reliable one to work with, especially when accuracy and durability are of utmost importance.

Designed to function in open loop hydraulic circuits, the D-1217 gives consistent results with superior efficiency. With an intended displacement rate of 82.24 cc/rev, this particular pump gives smooth outputs that respond instantly to the operational requirements. The unique feature here is that this pump is a variable delivery pump, offering the advantage of using power only when it is needed, avoiding the loss of efficiency that fixed displacement pumps create.

The D-1217 features a positive, variable delivery radial rolling piston design. This modern design helps the pump support higher pressure as well as ensures consistent flow rates. The pump has a maximum operating pressure of 2100 psi with peak pressures going higher, making it ideal for applications that need proper pressure control without the risk of component deterioration. The pump can support speeds of up to 1800 RPM.

Another benefit of the D-1217 Legacy Variable Displacement Pump is that it reacts instantly to the signals sent to it using electric hand servos or preset speed position controls. The pump reacts this fast to ensure that the operational speed is accurately controlled for the processing machinery. This is very useful because it eliminates the need for multiple directional or flow control valves to be used within the hydraulic system. This is because there are few pieces to maintain the system.

Furthermore, the D-1217 comes equipped with relief valves/high-pressure relief valves, gear pump/with relief valve, as well as a suction/return check valve with a check type. Such components provide a platform for both differential and non-differential two-way systems. Additionally, the reversing of fluid flow is cushioned smoothly.

Technical Specifications

PVG FAMILY SPECIFICATIONS

FRAME SIZE MODEL B-FRAME C-FRAME D-FRAME
PVG-048 PVG-065 PVG-075 PVG-100 PVG-130 PVG-150 PVG-180
DRIVE Maximum (RPM) 2700 2700 2700 2400 2400 2400 2400
Minimum (RPM) 600 600 600 600 600 600 600
Torque to turn shaft (ft. lbs.) 9 9 9 24 24 40 50
Rotational Moment of Inertia (lbs.-in2) 21 21 21 50 47 150 152
OUTPUT1 Pressure (PSIA) Peak 5800 5800 4250 5800 4250 5800 5800
Continuous 5000 5000 3750 5000 3750 5000 5000
Minimum 100 100 100 100 100 100 100
Nominal Volume (GPM) at 1800 RPM and Rated Pressure For Full Displacement 21.1 28.8 33.3 42.4 57.6 63.0 78.0
CASE2 Maximum Pressure (PSI) w/ Standard Shaft Seal 25 25 25 25 25 25 25
Minimum Drain Line Hose Size #16 SAE #16 SAE #16 SAE #16 SAE #16 SAE #16 SAE #16 SAE
CONTROLS3 Minimum Pressure (PSI) Pressure Controls – Minimum Compensator Setting 200 200 200 200 200 250 250
Volume Controls (VS, VM) – Minimum Pilot Pressure 500 500 500 500 500 500 800
Maximum Pilot Pressure (PSI) Volume Control – VS 600 600 600 600 600 600 N/A
Volume Control – VM 1000 1000 1000 1000 1000 1000 1000
Stroking Rate (MSEC) at Rated Pressure, Pressure Controls (Minimum) On Stroke 40 40 40 40 40 45 45
Off Stroke 50 50 50 50 50 60 60
Volume Controls (VS, VM) On Stroke 250 250 250 250 250 250 250
Off Stroke 250 250 250 250 250 250 250
FLUID4 Viscosity (SSU) Minimum 65 65 65 65 65 65 65
Maximum 2000 2000 2000 2000 2000 2000 2000
TEMPERATURE5 Fluid Operating Range (F˜) 14 to 190 14 to 190 14 to 190 14 to 190 14 to 190 14 to 190 14 to 190
Fluid Minimum Starting (F˜) -40 -40 -40 -40 -40 -40 -40
Fluid Maximum at Case Drain Port (F˜) 230 230 230 230 230 230 230