Oilgear D-10011 Legacy Variable Displacement Pump
Oilgear D-10011 Legacy Variable Displacement Pump
Rexton Hydraulic supplies and supports the Oilgear D-10011 Legacy Variable Displacement Pump with 802.96 cc/rev displacement, two-way flow control, and precise speed response—ideal for efficient open-loop industrial hydraulic systems.
- Series: D Type Pumps
- Displacement 21.36 – 802.96 cc/rev
- Continous Pressure 1500 – 4000 psi
- Maximum Speed 900 – 1800 RPM
- Variable Displacements Piston Pump
- Open Circuit Pump
Share Product:
Oilgear D-10011 Legacy Variable Displacement Pump is a heavy-duty two-way hydraulic pump designed and built to deliver precise flow control and superior efficiency under adverse operating conditions. Inherently part of the D-Series of pumps by Oilgear, which are renowned as ‘Legacies’ of reliable hydraulic performance through generations of successful design and development.
This is a type of open-loop hydraulic system, and it is designed using the model number D-10011. Its design incorporates a variable displacement and radial rolling piston that is capable of varying the hydraulic output depending on the demand of the system. One of the things that contribute to energy savings is the fact that it consumes power according to the operation that is being carried out.
The maximum displacement of 802.96cc/rev makes it possible for the Oilgear D-10011 to produce large hydraulic flow volumes with smooth and stable operation. The pump is capable of two-way flow, which enables reverse flow instantaneously without using intricate directional control valves. As a result, the hydraulic circuit will be simplified with fewer pipings.
D-10011: Max speed 900 RPM, rated for 1500 psi continuous pressure, makes them ideal applications requiring a controlled industrial process rather than shock-load. Instant response to electric hand servos or preset speed position controls delivers unparalleled accuracy in speed and motion control for processing machines.
Internally, it contains several radial rolling pistons, high-pressure relief valves, and a built-in gear pump with its own relief valve. It also has Oilgear’s pintle check-type suction and return valve. All these make the D-10011 suitable for operating in efficient differential and non-differential two-way systems with consistent pressure control and reliable startup performance.
By using Oilgear two-way variable displacement pumps, system designers can eliminate many external flow and directional valves, reduce electrical control requirements, cushion flow reversals, and achieve infinite flow variability. This leads to simpler systems, with less maintenance required, and far better long-term operating efficiency.
Technical Specifications
PVG FAMILY SPECIFICATIONS
| FRAME SIZE MODEL | B-FRAME | C-FRAME | D-FRAME | ||||||
| PVG-048 | PVG-065 | PVG-075 | PVG-100 | PVG-130 | PVG-150 | PVG-180 | |||
| DRIVE | Maximum (RPM) | 2700 | 2700 | 2700 | 2400 | 2400 | 2400 | 2400 | |
| Minimum (RPM) | 600 | 600 | 600 | 600 | 600 | 600 | 600 | ||
| Torque to turn shaft (ft. lbs.) | 9 | 9 | 9 | 24 | 24 | 40 | 50 | ||
| Rotational Moment of Inertia (lbs.-in2) | 21 | 21 | 21 | 50 | 47 | 150 | 152 | ||
| OUTPUT1 | Pressure (PSIA) | Peak | 5800 | 5800 | 4250 | 5800 | 4250 | 5800 | 5800 |
| Continuous | 5000 | 5000 | 3750 | 5000 | 3750 | 5000 | 5000 | ||
| Minimum | 100 | 100 | 100 | 100 | 100 | 100 | 100 | ||
| Nominal Volume (GPM) at 1800 RPM and Rated Pressure For Full Displacement | 21.1 | 28.8 | 33.3 | 42.4 | 57.6 | 63.0 | 78.0 | ||
| CASE2 | Maximum Pressure (PSI) w/ Standard Shaft Seal | 25 | 25 | 25 | 25 | 25 | 25 | 25 | |
| Minimum Drain Line Hose Size | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | ||
| CONTROLS3 | Minimum Pressure (PSI) | Pressure Controls – Minimum Compensator Setting | 200 | 200 | 200 | 200 | 200 | 250 | 250 |
| Volume Controls (VS, VM) – Minimum Pilot Pressure | 500 | 500 | 500 | 500 | 500 | 500 | 800 | ||
| Maximum Pilot Pressure (PSI) | Volume Control – VS | 600 | 600 | 600 | 600 | 600 | 600 | N/A | |
| Volume Control – VM | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | ||
| Stroking Rate (MSEC) at Rated Pressure, Pressure Controls (Minimum) | On Stroke | 40 | 40 | 40 | 40 | 40 | 45 | 45 | |
| Off Stroke | 50 | 50 | 50 | 50 | 50 | 60 | 60 | ||
| Volume Controls (VS, VM) | On Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | |
| Off Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | ||
| FLUID4 | Viscosity (SSU) | Minimum | 65 | 65 | 65 | 65 | 65 | 65 | 65 |
| Maximum | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | ||
| TEMPERATURE5 | Fluid Operating Range (F˜) | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | |
| Fluid Minimum Starting (F˜) | -40 | -40 | -40 | -40 | -40 | -40 | -40 | ||
| Fluid Maximum at Case Drain Port (F˜) | 230 | 230 | 230 | 230 | 230 | 230 | 230 | ||