Oilgear D-6011 Legacy Variable Displacement Pump

Oilgear D-6011 Legacy Variable Displacement Pump

We offer sales and services for Oilgear D-6011 Legacy Variable Displacement Pump. This is a legacy two-way variable displacement hydraulic pump designed for smooth speed control, efficient flow regulation and reliable performance in heavy-duty industrial applications.
 

  • Series: D Type Pumps
  • Displacement 21.36 – 802.96 cc/rev
  • Continous Pressure 1500 – 4000 psi
  • Maximum Speed 900 – 1800 RPM
  • Variable Displacements Piston Pump
  • Open Circuit Pump

Share Product:

Oilgear D-6011 Legacy Variable Displacement Pump is a heavy-duty two-way hydraulic pump suitable for precise flow control. It comes as part of the highly respected D Series range of Oilgear hydraulic pumps. When it comes to heavy-duty use with high-pressure applications over extended periods of time, the D-6011 is recognized for its robust build and dependable performance.

It uses an open-loop hydraulic system to provide the VARIABLE DISPLACEMENT based on the respective demands. In this way, the D-6011 eliminates the chances of LOSS OF PRESSURE or increased generations of HEAT in the system. Furthermore, the cylinder reacts immediately to the control of the electric hand servos or the speed position control to meet the demands of a machine requiring a smooth variation in the speeds.

With its maximum displacement of 468.48 cc/rev, the Oilgear D-6011 is capable of handling high-flow demands. The maximum continuous pressure of 1500 psi, as well as its peak pressure of up to 3000 psi, makes it reliable even at fluctuating levels. Additionally, its speed of 1200 RPM ensures that the flow is provided without causing much wear to its components.

The internal design consists of positive variable delivery, multi-radial rolling pistons, high-pressure relief valves, and gear pumps with relief valves. Moreover, the pintle check-type suction and return valve made by Oilgear is designed for efficient function in the differential as well as non-differential two-way systems.

With the help of the Oilgear D-6011, system designers are also capable of eliminating a variety of directional and flow control valves in the system. The pump further dampens flow reversals, reduces electrical control, and features infinite flow variation capability.

Oilgear does recommend upgrading the older D Type pumps such as the D-6011 to the current model PVV pumps where possible. The D-6011 remains a trusted option for applications involving the servicing, replacement, or retrofitting of older hydraulic systems.

Technical Specifications

PVG FAMILY SPECIFICATIONS

FRAME SIZE MODEL B-FRAME C-FRAME D-FRAME
PVG-048 PVG-065 PVG-075 PVG-100 PVG-130 PVG-150 PVG-180
DRIVE Maximum (RPM) 2700 2700 2700 2400 2400 2400 2400
Minimum (RPM) 600 600 600 600 600 600 600
Torque to turn shaft (ft. lbs.) 9 9 9 24 24 40 50
Rotational Moment of Inertia (lbs.-in2) 21 21 21 50 47 150 152
OUTPUT1 Pressure (PSIA) Peak 5800 5800 4250 5800 4250 5800 5800
Continuous 5000 5000 3750 5000 3750 5000 5000
Minimum 100 100 100 100 100 100 100
Nominal Volume (GPM) at 1800 RPM and Rated Pressure For Full Displacement 21.1 28.8 33.3 42.4 57.6 63.0 78.0
CASE2 Maximum Pressure (PSI) w/ Standard Shaft Seal 25 25 25 25 25 25 25
Minimum Drain Line Hose Size #16 SAE #16 SAE #16 SAE #16 SAE #16 SAE #16 SAE #16 SAE
CONTROLS3 Minimum Pressure (PSI) Pressure Controls – Minimum Compensator Setting 200 200 200 200 200 250 250
Volume Controls (VS, VM) – Minimum Pilot Pressure 500 500 500 500 500 500 800
Maximum Pilot Pressure (PSI) Volume Control – VS 600 600 600 600 600 600 N/A
Volume Control – VM 1000 1000 1000 1000 1000 1000 1000
Stroking Rate (MSEC) at Rated Pressure, Pressure Controls (Minimum) On Stroke 40 40 40 40 40 45 45
Off Stroke 50 50 50 50 50 60 60
Volume Controls (VS, VM) On Stroke 250 250 250 250 250 250 250
Off Stroke 250 250 250 250 250 250 250
FLUID4 Viscosity (SSU) Minimum 65 65 65 65 65 65 65
Maximum 2000 2000 2000 2000 2000 2000 2000
TEMPERATURE5 Fluid Operating Range (F˜) 14 to 190 14 to 190 14 to 190 14 to 190 14 to 190 14 to 190 14 to 190
Fluid Minimum Starting (F˜) -40 -40 -40 -40 -40 -40 -40
Fluid Maximum at Case Drain Port (F˜) 230 230 230 230 230 230 230