Oilgear D-3517 Legacy Variable Displacement Pump
Oilgear D-3517 Legacy Variable Displacement Pump
Rexton Hydraulic offers sales, repair and replacement solutions for the Oilgear D-3517 Legacy Variable Displacement Pump. Designed for precise speed control, smooth flow reversal, and reliable performance in heavy-duty hydraulic systems.
- Series: D Type Pumps
- Displacement 21.36 – 802.96 cc/rev
- Continous Pressure 1500 – 4000 psi
- Maximum Speed 900 – 1800 RPM
- Variable Displacements Piston Pump
- Open Circuit Pump
Share Product:
Oilgear D-3517 Legacy Variable Displacement Pump is a well-established two-way hydraulic pump that is known for its speed control and reliability in industrial applications. It was manufactured as part of Oilgear’s famous D Series range and comes from a product line with a legacy that was established with several decades of reliability in tough processing applications.
D-3517 employs a variable displacement, radial rolling piston system, which provides a hydraulic output proportional to the system requirements. This minimizes power wastage, which could result from either fluid bypass, overheating, or pressure drop. Also, there is a heightened responsiveness to either electronic hand servos or preset speed position controls, which makes it suitable for applications requiring a smooth acceleration, controlled deceleration, and stable flow reversal.
The D-3517 pump is designed for use in open loop hydraulic systems and works effectively in a maximum continuous pressure of 2100 psi and a maximum operating speed of 1200 RPM. Its internal design ensures a reliable service life, regardless of whether the system remains loaded or varies due to continuous service. The D-3517 pump features built-in high-pressure relief valves, pintle-type suction and return valves, and customizable control systems to simplify the configuration of the hydraulic system, thereby eliminating the necessity for other control valves.
With infinite flow variation capability, as well as a cushioned flow reversal feature, the Oilgear D-3517 works towards enhancing the responsiveness, efficiency, and design simplicity of hydraulic circuits. Even when Oilgear promotes its customers to upgrade to the new generation of PVV pumps, specifically designed for older D Series pumps, still, there is support for D-3517 when it comes to aftermarket services.
Rexton Hydraulic will provide a sales, repair, or replacement solution for the Oilgear D-3517 Legacy Variable Displacement Pump model. The D-3517 is still popular today for excellent speed control, reversing, and robust operation in heavy-duty hydraulic applications, despite being somewhat outdated regarding modern hydraulic pump technology.
Technical Specifications
PVG FAMILY SPECIFICATIONS
| FRAME SIZE MODEL | B-FRAME | C-FRAME | D-FRAME | ||||||
| PVG-048 | PVG-065 | PVG-075 | PVG-100 | PVG-130 | PVG-150 | PVG-180 | |||
| DRIVE | Maximum (RPM) | 2700 | 2700 | 2700 | 2400 | 2400 | 2400 | 2400 | |
| Minimum (RPM) | 600 | 600 | 600 | 600 | 600 | 600 | 600 | ||
| Torque to turn shaft (ft. lbs.) | 9 | 9 | 9 | 24 | 24 | 40 | 50 | ||
| Rotational Moment of Inertia (lbs.-in2) | 21 | 21 | 21 | 50 | 47 | 150 | 152 | ||
| OUTPUT1 | Pressure (PSIA) | Peak | 5800 | 5800 | 4250 | 5800 | 4250 | 5800 | 5800 |
| Continuous | 5000 | 5000 | 3750 | 5000 | 3750 | 5000 | 5000 | ||
| Minimum | 100 | 100 | 100 | 100 | 100 | 100 | 100 | ||
| Nominal Volume (GPM) at 1800 RPM and Rated Pressure For Full Displacement | 21.1 | 28.8 | 33.3 | 42.4 | 57.6 | 63.0 | 78.0 | ||
| CASE2 | Maximum Pressure (PSI) w/ Standard Shaft Seal | 25 | 25 | 25 | 25 | 25 | 25 | 25 | |
| Minimum Drain Line Hose Size | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | ||
| CONTROLS3 | Minimum Pressure (PSI) | Pressure Controls – Minimum Compensator Setting | 200 | 200 | 200 | 200 | 200 | 250 | 250 |
| Volume Controls (VS, VM) – Minimum Pilot Pressure | 500 | 500 | 500 | 500 | 500 | 500 | 800 | ||
| Maximum Pilot Pressure (PSI) | Volume Control – VS | 600 | 600 | 600 | 600 | 600 | 600 | N/A | |
| Volume Control – VM | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | ||
| Stroking Rate (MSEC) at Rated Pressure, Pressure Controls (Minimum) | On Stroke | 40 | 40 | 40 | 40 | 40 | 45 | 45 | |
| Off Stroke | 50 | 50 | 50 | 50 | 50 | 60 | 60 | ||
| Volume Controls (VS, VM) | On Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | |
| Off Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | ||
| FLUID4 | Viscosity (SSU) | Minimum | 65 | 65 | 65 | 65 | 65 | 65 | 65 |
| Maximum | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | ||
| TEMPERATURE5 | Fluid Operating Range (F˜) | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | |
| Fluid Minimum Starting (F˜) | -40 | -40 | -40 | -40 | -40 | -40 | -40 | ||
| Fluid Maximum at Case Drain Port (F˜) | 230 | 230 | 230 | 230 | 230 | 230 | 230 | ||