Oilgear C-3517 Radial Rolling Piston Pump
Oilgear C-3517 Radial Rolling Piston Pump
At Rexton Hydraulic, we supply, service, repair and support the Oilgear C-3517 Radial Rolling Piston Pump, ensuring correct selection, expert maintenance, and long-term operational reliability for industrial open-loop hydraulic systems.
- Series: C Type Pumps
- Displacement 21.36 – 802.96 cc/rev
- Continous Pressure 1500 – 4000 psi
- Maximum Speed 900 – 1800 RPM
- Radial Piston Pump
- Open Circuit Pump
Share Product:
Oilgear C-3517 Radial Rolling Piston Pump is a constant delivery one-way hydraulic pump specifically designed for open-loop hydronic systems requiring positive flow, positive pressure control, or long life. Because the C-3517 pump is part of the proven C-Series lineup offered by Oilgear, the accompanying tradition of radial rolling piston excellence that has been the standard within the industry since 1921 has been maintained."
The C-3517 is designed for an industrial environment and offers smooth and efficient hydraulic performance and minimal pulsation. The pump maintains a fixed displacement, and it is very suitable for use in machines that work under a constant load or fluid delivery. The design of the pump maintains the efficiency of the pump even when it is working in a very demanding environment and a critical uptime situation.
Oilgear C-3517 pump has a displacement capacity of a maximum of 176.37 cc/rev, which is quite sufficient to discharge a large amount of fluid flow, depending upon the pump size, system pressure, and speed of the drive shaft. The pump has a discharge mechanism that allows fluid to flow in only one direction, but system designs offer a provision by which directional control valves are utilized to reverse fluid flow if needed.
The Oilgear C-3517 has a highest operating speed of 1200 RPM with a top pressure rating of 2500 psi and a peak pressure of 3000 psi. The pressure and operational speeds of this pump are ideal in handling heavy-duty applications without failing due to increased pressure. An adjustable relief valve attached to the pump increases safety in the operational setup.
Offered in clockwise, counterclockwise, or reverse rotation of input shaft, this Oilgear model C-3517 has flexibility in terms of equipment orientation. The CG-type versions include combinations of radial rolling piston pump with integral gear pumps and relief valves, as well as suction, check, and back-pressure relief for use in supercharge.
Technical Specifications
PVG FAMILY SPECIFICATIONS
| FRAME SIZE MODEL | B-FRAME | C-FRAME | D-FRAME | ||||||
| PVG-048 | PVG-065 | PVG-075 | PVG-100 | PVG-130 | PVG-150 | PVG-180 | |||
| DRIVE | Maximum (RPM) | 2700 | 2700 | 2700 | 2400 | 2400 | 2400 | 2400 | |
| Minimum (RPM) | 600 | 600 | 600 | 600 | 600 | 600 | 600 | ||
| Torque to turn shaft (ft. lbs.) | 9 | 9 | 9 | 24 | 24 | 40 | 50 | ||
| Rotational Moment of Inertia (lbs.-in2) | 21 | 21 | 21 | 50 | 47 | 150 | 152 | ||
| OUTPUT1 | Pressure (PSIA) | Peak | 5800 | 5800 | 4250 | 5800 | 4250 | 5800 | 5800 |
| Continuous | 5000 | 5000 | 3750 | 5000 | 3750 | 5000 | 5000 | ||
| Minimum | 100 | 100 | 100 | 100 | 100 | 100 | 100 | ||
| Nominal Volume (GPM) at 1800 RPM and Rated Pressure For Full Displacement | 21.1 | 28.8 | 33.3 | 42.4 | 57.6 | 63.0 | 78.0 | ||
| CASE2 | Maximum Pressure (PSI) w/ Standard Shaft Seal | 25 | 25 | 25 | 25 | 25 | 25 | 25 | |
| Minimum Drain Line Hose Size | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | ||
| CONTROLS3 | Minimum Pressure (PSI) | Pressure Controls – Minimum Compensator Setting | 200 | 200 | 200 | 200 | 200 | 250 | 250 |
| Volume Controls (VS, VM) – Minimum Pilot Pressure | 500 | 500 | 500 | 500 | 500 | 500 | 800 | ||
| Maximum Pilot Pressure (PSI) | Volume Control – VS | 600 | 600 | 600 | 600 | 600 | 600 | N/A | |
| Volume Control – VM | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | ||
| Stroking Rate (MSEC) at Rated Pressure, Pressure Controls (Minimum) | On Stroke | 40 | 40 | 40 | 40 | 40 | 45 | 45 | |
| Off Stroke | 50 | 50 | 50 | 50 | 50 | 60 | 60 | ||
| Volume Controls (VS, VM) | On Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | |
| Off Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | ||
| FLUID4 | Viscosity (SSU) | Minimum | 65 | 65 | 65 | 65 | 65 | 65 | 65 |
| Maximum | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | ||
| TEMPERATURE5 | Fluid Operating Range (F˜) | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | |
| Fluid Minimum Starting (F˜) | -40 | -40 | -40 | -40 | -40 | -40 | -40 | ||
| Fluid Maximum at Case Drain Port (F˜) | 230 | 230 | 230 | 230 | 230 | 230 | 230 | ||