Oilgear PVWW-130 Variable Displacement Hydraulic Pump
Oilgear PVWW-130 Variable Displacement Hydraulic Pump
Rexton Hydraulic supplies the Oilgear PVWW-130 Variable Displacement Axial Piston Pump, featuring 130.2 ml/rev displacement, 82.7 bar continuous pressure and 214.2 l/min flow at 1800 RPM for low-lubricity hydraulic applications.
- Series: PVWW Legacy Pumps
- Displacement 14 – 130 cc/rev
- Continous Pressure 200 Bar
- Maximum Speed 1800 RPM
- Variable Displacement Pump
- Open Circuit Pump
Share Product:
Oilgear PVWW-130 Variable Displacement Axial Piston Hydraulic Pump is designed for open-loop hydraulic systems requiring reliable performance in hydraulic and low-lubricity fluids. As part of Oilgear's PVWW Series, this pump was developed specially for applications with high water-content fluids, which most conventional hydraulic pumps often face lubrication and wear challenges. Its rugged construction and stable control characteristics make it a fitting solution for demanding industrial hydraulic systems.
With a maximum theoretical displacement of 130.2 ml/rev, the PVWW-130 delivers high volumetric output with controlled and responsive flow regulation. The variable displacement design allows the pump to automatically adjust output based on system demand, improving energy efficiency, minimizing heat generation, and ensuring smooth system performance against changing load conditions. These features make it particularly valuable in applications with fluctuating operational requirements.
The pump is rated to operate continuously at a pressure of 82.7 bar and can withstand a peak pressure of 103.4 bar, affording stable operation during continuous running and short-duration pressure spikes. Operating at a maximum speed of 1800 RPM, the PVWW-130 offers a robust flow of 56.5 gpm against rated continuous pressure, with standard inlet conditions. This sits well with higher-capacity hydraulic circuits that need consistent and reliable flow delivery.
The PVWW-130 is based on a Frame Size C housing, with SAE "C" 2-bolt face mounting for easy installation, and thus compatibility with a wide range of hydraulic power units and industrial machinery. With a weight of 46.8 kg, the pump reflects robust internal construction designed for long-term durability. Flexible top, bottom, and rear port locations further simplify system integration and layout planning.
Typical applications of Oilgear PVWW-130 include general industrial machinery, hydraulic power units, material handling systems, steel and metal processing equipment, and hydraulic systems using high water-content or environmentally sensitive fluids. At Rexton Hydraulic, we supply, install, repair, and service the Oilgear PVWW-130 pump, providing expert support, correct pump selection and long-term reliability for critical hydraulic applications.
Technical Specifications
PVG FAMILY SPECIFICATIONS
| FRAME SIZE MODEL | B-FRAME | C-FRAME | D-FRAME | ||||||
| PVG-048 | PVG-065 | PVG-075 | PVG-100 | PVG-130 | PVG-150 | PVG-180 | |||
| DRIVE | Maximum (RPM) | 2700 | 2700 | 2700 | 2400 | 2400 | 2400 | 2400 | |
| Minimum (RPM) | 600 | 600 | 600 | 600 | 600 | 600 | 600 | ||
| Torque to turn shaft (ft. lbs.) | 9 | 9 | 9 | 24 | 24 | 40 | 50 | ||
| Rotational Moment of Inertia (lbs.-in2) | 21 | 21 | 21 | 50 | 47 | 150 | 152 | ||
| OUTPUT1 | Pressure (PSIA) | Peak | 5800 | 5800 | 4250 | 5800 | 4250 | 5800 | 5800 |
| Continuous | 5000 | 5000 | 3750 | 5000 | 3750 | 5000 | 5000 | ||
| Minimum | 100 | 100 | 100 | 100 | 100 | 100 | 100 | ||
| Nominal Volume (GPM) at 1800 RPM and Rated Pressure For Full Displacement | 21.1 | 28.8 | 33.3 | 42.4 | 57.6 | 63.0 | 78.0 | ||
| CASE2 | Maximum Pressure (PSI) w/ Standard Shaft Seal | 25 | 25 | 25 | 25 | 25 | 25 | 25 | |
| Minimum Drain Line Hose Size | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | ||
| CONTROLS3 | Minimum Pressure (PSI) | Pressure Controls – Minimum Compensator Setting | 200 | 200 | 200 | 200 | 200 | 250 | 250 |
| Volume Controls (VS, VM) – Minimum Pilot Pressure | 500 | 500 | 500 | 500 | 500 | 500 | 800 | ||
| Maximum Pilot Pressure (PSI) | Volume Control – VS | 600 | 600 | 600 | 600 | 600 | 600 | N/A | |
| Volume Control – VM | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | ||
| Stroking Rate (MSEC) at Rated Pressure, Pressure Controls (Minimum) | On Stroke | 40 | 40 | 40 | 40 | 40 | 45 | 45 | |
| Off Stroke | 50 | 50 | 50 | 50 | 50 | 60 | 60 | ||
| Volume Controls (VS, VM) | On Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | |
| Off Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | ||
| FLUID4 | Viscosity (SSU) | Minimum | 65 | 65 | 65 | 65 | 65 | 65 | 65 |
| Maximum | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | ||
| TEMPERATURE5 | Fluid Operating Range (F˜) | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | |
| Fluid Minimum Starting (F˜) | -40 | -40 | -40 | -40 | -40 | -40 | -40 | ||
| Fluid Maximum at Case Drain Port (F˜) | 230 | 230 | 230 | 230 | 230 | 230 | 230 | ||