Oilgear PVM-014 Variable Displacement Hydraulic Pump
Oilgear PVM-014 Variable Displacement Hydraulic Pump
Rexton Hydraulic is a well-known supplier and service provider of Oilgear PVM-014 Variable Displacement Axial Piston Pump. Comes in 14 cc/rev displacement, 260 bar pressure capacity, and variable flow control, these are perfect for compact and responsive hydraulic systems.
- Series: PVM Legacy Pumps
- Displacement 11 – 130 cc/rev
- Continuous Pressure 206 Bar
- Maximum Speed 2400 – 3600 RPM
- Variable Displacement Pump
- Open Circuit Pump
Share Product:
The Oilgear PVM-014 is a compact yet versatile variable-displacement axial piston pump. The maximum displacement per revolution of 14 cc/rev permits hydraulic flow regulation and adequate response of the system for several applications, from small- to medium-power hydraulic systems, auxiliary circuits, and equipment where precision matters.
The open-loop design of the pump makes integration into a system easier, at the same time reducing control complexities. It supports a maximum continuous operating pressure of 260 bar in conjunction with a maximum shaft speed of 3600 RPM, enabling the PVM-014 to deliver consistent output at high rotational speeds.
The PVM-014 flow rate is about 5.8 gallons per minute at 1800 RPM, under rated continuous pressure, enough for the light hydraulic function, compact machinery, and auxiliary circuits requiring smooth, controllable fluid flow.
Oilgear designed the PVM-014 with focus on internal durability and fluid flexibility. The hardened surfaces and precision machining on the rotating group and piston assembly provide low wear and extended service life. It accepts modern hydraulic fluids, including low-lubricity and specialty fluids, thereby allowing users several options in fluid selection without sacrificing performance.
Due to its variable-displacement design, PVM-014 provides the facility for adjusting flow according to system demand. This makes it ideal for systems where hydraulic load varies, including mobile machinery, servo-controlled applications, clamping units, compact presses, or auxiliary hydraulic functions. Its responsiveness and control accuracy give engineers flexibility to optimize performance and energy use.
With its compact and robust design, the pump easily installs-even in space restrictive areas. Its mid-range displacement and pressure capability provides an excellent balance of output, efficiency, and system simplicity. For new hydraulic builds or retrofit set-ups, PVM-014 presents a dependable, economical selection option.
Rexton Hydraulic deals in sales and services of the full PVM pump range including PVM-014. We help you choose the right pump configuration, advise on integration, and provide maintenance support — ensuring your hydraulic systems perform smoothly and reliably over long operating life.
Technical Specifications
PVG FAMILY SPECIFICATIONS
| FRAME SIZE MODEL | B-FRAME | C-FRAME | D-FRAME | ||||||
| PVG-048 | PVG-065 | PVG-075 | PVG-100 | PVG-130 | PVG-150 | PVG-180 | |||
| DRIVE | Maximum (RPM) | 2700 | 2700 | 2700 | 2400 | 2400 | 2400 | 2400 | |
| Minimum (RPM) | 600 | 600 | 600 | 600 | 600 | 600 | 600 | ||
| Torque to turn shaft (ft. lbs.) | 9 | 9 | 9 | 24 | 24 | 40 | 50 | ||
| Rotational Moment of Inertia (lbs.-in2) | 21 | 21 | 21 | 50 | 47 | 150 | 152 | ||
| OUTPUT1 | Pressure (PSIA) | Peak | 5800 | 5800 | 4250 | 5800 | 4250 | 5800 | 5800 |
| Continuous | 5000 | 5000 | 3750 | 5000 | 3750 | 5000 | 5000 | ||
| Minimum | 100 | 100 | 100 | 100 | 100 | 100 | 100 | ||
| Nominal Volume (GPM) at 1800 RPM and Rated Pressure For Full Displacement | 21.1 | 28.8 | 33.3 | 42.4 | 57.6 | 63.0 | 78.0 | ||
| CASE2 | Maximum Pressure (PSI) w/ Standard Shaft Seal | 25 | 25 | 25 | 25 | 25 | 25 | 25 | |
| Minimum Drain Line Hose Size | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | ||
| CONTROLS3 | Minimum Pressure (PSI) | Pressure Controls – Minimum Compensator Setting | 200 | 200 | 200 | 200 | 200 | 250 | 250 |
| Volume Controls (VS, VM) – Minimum Pilot Pressure | 500 | 500 | 500 | 500 | 500 | 500 | 800 | ||
| Maximum Pilot Pressure (PSI) | Volume Control – VS | 600 | 600 | 600 | 600 | 600 | 600 | N/A | |
| Volume Control – VM | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | ||
| Stroking Rate (MSEC) at Rated Pressure, Pressure Controls (Minimum) | On Stroke | 40 | 40 | 40 | 40 | 40 | 45 | 45 | |
| Off Stroke | 50 | 50 | 50 | 50 | 50 | 60 | 60 | ||
| Volume Controls (VS, VM) | On Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | |
| Off Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | ||
| FLUID4 | Viscosity (SSU) | Minimum | 65 | 65 | 65 | 65 | 65 | 65 | 65 |
| Maximum | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | ||
| TEMPERATURE5 | Fluid Operating Range (F˜) | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | |
| Fluid Minimum Starting (F˜) | -40 | -40 | -40 | -40 | -40 | -40 | -40 | ||
| Fluid Maximum at Case Drain Port (F˜) | 230 | 230 | 230 | 230 | 230 | 230 | 230 | ||