Oilgear PVWJ-130 Variable Displacement Axial Piston Pump
Oilgear PVWJ-130 Variable Displacement Axial Piston Pump
Rexton Hydraulic supplies the Oilgear PVWJ-130 Variable Displacement Axial Piston Pump, offering high 130 cc/rev displacement, medium-control response and long-lasting durability for industrial and mobile hydraulic systems.
- Series: PVWJ Pump
- Displacement 11.0 cc/rev – 130.0 cc/rev
- Nominal Pressure 103 Bar
- Maximum Pressure 345 Bar
- Maximum Speed 2100-3600 RPM
- High-Pressure Pump
- Open Circuit Pump
Share Product:
The Oilgear PVWJ-130 Variable Displacement Axial Piston Pump is designed for hydraulic systems that need high flow output, reliable performance and compact, easy to integrate design. With a displacement of 130 cc/rev it delivers high volume hydraulic flow for medium to heavy duty equipment. This pump works well in industrial machinery, large mobile systems and hydraulic units where performance is critical.
The pump operates in open loop and is designed to run up to 2100 RPM. It supports continuous operating pressure for medium pressure hydraulic applications so it’s reliable for systems that need flow rather than high pressure. Its combination of high displacement and moderate pressure makes the PVWJ-130 ideal for powering larger actuators, multiple hydraulic functions or machinery that runs for long hours under steady load.
Oilgear engineered the PVWJ-130 with durability in mind. The rotating group, swashplate assembly and wear surfaces are made with hardened materials to reduce friction and maintain smooth operation over extended use. The pump works with modern hydraulic fluids including low viscosity options to maintain stable lubrication, cooler operation and longer life. These internal design features reduce wear and keep maintenance to a minimum.
This model also has stable and predictable control response. It has medium speed displacement adjustment so it’s smooth when system flow demand changes. This makes the pump suitable for applications like presses, lifting systems, material handling machines, hydraulic power packs and mobile equipment that need consistent and steady hydraulic behavior.
The PVWJ-130 has multiple porting layouts, shaft configurations, mounting options and rotation directions. This makes it easy to fit into existing hydraulic systems or new builds with minimal modification. Despite its higher displacement the pump is compact and practical for systems where space is limited but output is high. Overall the Oilgear PVWJ-130 delivers high flow capacity, smooth control, long term durability and installation flexibility.
Technical Specifications
PVG FAMILY SPECIFICATIONS
| FRAME SIZE MODEL | B-FRAME | C-FRAME | D-FRAME | ||||||
| PVG-048 | PVG-065 | PVG-075 | PVG-100 | PVG-130 | PVG-150 | PVG-180 | |||
| DRIVE | Maximum (RPM) | 2700 | 2700 | 2700 | 2400 | 2400 | 2400 | 2400 | |
| Minimum (RPM) | 600 | 600 | 600 | 600 | 600 | 600 | 600 | ||
| Torque to turn shaft (ft. lbs.) | 9 | 9 | 9 | 24 | 24 | 40 | 50 | ||
| Rotational Moment of Inertia (lbs.-in2) | 21 | 21 | 21 | 50 | 47 | 150 | 152 | ||
| OUTPUT1 | Pressure (PSIA) | Peak | 5800 | 5800 | 4250 | 5800 | 4250 | 5800 | 5800 |
| Continuous | 5000 | 5000 | 3750 | 5000 | 3750 | 5000 | 5000 | ||
| Minimum | 100 | 100 | 100 | 100 | 100 | 100 | 100 | ||
| Nominal Volume (GPM) at 1800 RPM and Rated Pressure For Full Displacement | 21.1 | 28.8 | 33.3 | 42.4 | 57.6 | 63.0 | 78.0 | ||
| CASE2 | Maximum Pressure (PSI) w/ Standard Shaft Seal | 25 | 25 | 25 | 25 | 25 | 25 | 25 | |
| Minimum Drain Line Hose Size | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | ||
| CONTROLS3 | Minimum Pressure (PSI) | Pressure Controls – Minimum Compensator Setting | 200 | 200 | 200 | 200 | 200 | 250 | 250 |
| Volume Controls (VS, VM) – Minimum Pilot Pressure | 500 | 500 | 500 | 500 | 500 | 500 | 800 | ||
| Maximum Pilot Pressure (PSI) | Volume Control – VS | 600 | 600 | 600 | 600 | 600 | 600 | N/A | |
| Volume Control – VM | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | ||
| Stroking Rate (MSEC) at Rated Pressure, Pressure Controls (Minimum) | On Stroke | 40 | 40 | 40 | 40 | 40 | 45 | 45 | |
| Off Stroke | 50 | 50 | 50 | 50 | 50 | 60 | 60 | ||
| Volume Controls (VS, VM) | On Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | |
| Off Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | ||
| FLUID4 | Viscosity (SSU) | Minimum | 65 | 65 | 65 | 65 | 65 | 65 | 65 |
| Maximum | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | ||
| TEMPERATURE5 | Fluid Operating Range (F˜) | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | |
| Fluid Minimum Starting (F˜) | -40 | -40 | -40 | -40 | -40 | -40 | -40 | ||
| Fluid Maximum at Case Drain Port (F˜) | 230 | 230 | 230 | 230 | 230 | 230 | 230 | ||