Oilgear PVWJ-014 Variable Displacement Axial Piston Pump
Oilgear PVWJ-014 Variable Displacement Axial Piston Pump
At Rexton Hydraulic we supply, maintain and service the full PVWJ range so your hydraulic system runs smoothly with minimal downtime. The Oilgear PVWJ-014 is a reliable choice for precision driven applications where accuracy, efficiency and long term reliability is key.
- Series: PVWJ Pump
- Displacement 11.0 cc/rev – 130.0 cc/rev
- Nominal Pressure 103 Bar
- Maximum Pressure 345 Bar
- Maximum Speed 2100-3600 RPM
- High-Pressure Pump
- Open Circuit Pump
Share Product:
The Oilgear PVWJ-014 Variable Displacement Axial Piston Pump is designed for hydraulic systems that need precise control, compact installation and continuous operation. With a displacement of 14 cc/rev this pump is ideal for small to medium hydraulic applications where accuracy, smooth response and efficient flow is key. It’s used in automated machinery, specialized industrial systems, compact mobile equipment and applications where space is limited but high reliability is required.
Despite its compact size the PVWJ-014 is engineered to handle high operating pressures and maintain hydraulic output. It’s an open loop pump and supports high rotational speeds so it can deliver flow even during demanding duty cycles. This makes the pump suitable for systems that run for long hours, need quick reaction to load changes or smooth transitions between different hydraulic functions.
Oilgear has designed the PVWJ-014 with durability in mind. It has hardened internal components, pressure lubricated moving surfaces and a robust rotating group for excellent wear resistance. The internal build allows for low viscosity hydraulic fluids so it’s suitable for modern hydraulic environments where fluid characteristics vary. These design elements reduce maintenance frequency, extend pump life and ensures performance across different working conditions.
One of the best features of the PVWJ-014 is its precision displacement control. The pump responds quickly when system demands change allowing accurate flow adjustment without delay. This level of control is valuable for machines that need stable pressure, predictable movement and responsive hydraulic action. It’s especially useful in systems with frequent cycling, servo type control loops or where performance is critical to operation.
The pump also has flexible installation options. It has multiple shaft designs, porting styles and rotation directions so it can be easily integrated into older systems or new hydraulic layouts. Its compact footprint saves space while still delivering strong hydraulic performance.
Technical Specifications
PVG FAMILY SPECIFICATIONS
| FRAME SIZE MODEL | B-FRAME | C-FRAME | D-FRAME | ||||||
| PVG-048 | PVG-065 | PVG-075 | PVG-100 | PVG-130 | PVG-150 | PVG-180 | |||
| DRIVE | Maximum (RPM) | 2700 | 2700 | 2700 | 2400 | 2400 | 2400 | 2400 | |
| Minimum (RPM) | 600 | 600 | 600 | 600 | 600 | 600 | 600 | ||
| Torque to turn shaft (ft. lbs.) | 9 | 9 | 9 | 24 | 24 | 40 | 50 | ||
| Rotational Moment of Inertia (lbs.-in2) | 21 | 21 | 21 | 50 | 47 | 150 | 152 | ||
| OUTPUT1 | Pressure (PSIA) | Peak | 5800 | 5800 | 4250 | 5800 | 4250 | 5800 | 5800 |
| Continuous | 5000 | 5000 | 3750 | 5000 | 3750 | 5000 | 5000 | ||
| Minimum | 100 | 100 | 100 | 100 | 100 | 100 | 100 | ||
| Nominal Volume (GPM) at 1800 RPM and Rated Pressure For Full Displacement | 21.1 | 28.8 | 33.3 | 42.4 | 57.6 | 63.0 | 78.0 | ||
| CASE2 | Maximum Pressure (PSI) w/ Standard Shaft Seal | 25 | 25 | 25 | 25 | 25 | 25 | 25 | |
| Minimum Drain Line Hose Size | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | ||
| CONTROLS3 | Minimum Pressure (PSI) | Pressure Controls – Minimum Compensator Setting | 200 | 200 | 200 | 200 | 200 | 250 | 250 |
| Volume Controls (VS, VM) – Minimum Pilot Pressure | 500 | 500 | 500 | 500 | 500 | 500 | 800 | ||
| Maximum Pilot Pressure (PSI) | Volume Control – VS | 600 | 600 | 600 | 600 | 600 | 600 | N/A | |
| Volume Control – VM | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | ||
| Stroking Rate (MSEC) at Rated Pressure, Pressure Controls (Minimum) | On Stroke | 40 | 40 | 40 | 40 | 40 | 45 | 45 | |
| Off Stroke | 50 | 50 | 50 | 50 | 50 | 60 | 60 | ||
| Volume Controls (VS, VM) | On Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | |
| Off Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | ||
| FLUID4 | Viscosity (SSU) | Minimum | 65 | 65 | 65 | 65 | 65 | 65 | 65 |
| Maximum | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | ||
| TEMPERATURE5 | Fluid Operating Range (F˜) | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | |
| Fluid Minimum Starting (F˜) | -40 | -40 | -40 | -40 | -40 | -40 | -40 | ||
| Fluid Maximum at Case Drain Port (F˜) | 230 | 230 | 230 | 230 | 230 | 230 | 230 | ||