Oilgear PVG-150 Variable Displacement Axial Piston Pump
Oilgear PVG-150 Variable Displacement Axial Piston Pump
Oilgear PVG-150 is the perfect choice for users who need a high capacity hydraulic pump with strong performance and low maintenance. At Rexton Hydraulic we supply, service and repair the complete PVG range. Our team will make sure your pump runs smooth and delivers output in every application.
- Series: PVG Pump
- Displacement 100 – 150 cc/rev
- Nominal Pressure 300 Bar
- Maximum Pressure 400 Bar
- Maximum Speed 2000 – 3000 RPM
- High-Pressure Pump
- Open Circuit Pump
Share Product:
The Oilgear PVG-150 Variable Displacement Axial Piston Pump is for applications that need steady power and hydraulic performance. It has a large displacement of 150 cc/rev for machines that work heavy and long cycles. The pump is open loop and maintains output under shifting loads which improves system stability.
This pump handles high pressure with ease. It works at continuous pressure up to 345 bar and peak values when needed. It runs at speeds up to 2,400 RPM and supplies high flow while keeping energy consumption low. This balance of speed and pressure is perfect for industrial machines, mobile equipment, heavy construction units and large hydraulic power packs.
Oilgear has engineered the PVG-150 for reliability in harsh environments. The internal structure has a hydrodynamic bearing that supports the cylinder barrel during high load operation. This reduces friction and protects internal components. The rotating group has hardened contact surfaces that improve wear resistance. This design allows the pump to tolerate contamination and maintain smooth operation even in poor fluid conditions.
The pump responds quickly to control signals. A pilot operated displacement control regulates the output and maintains smooth transitions. This allows precise motion control and quick adjustments in demanding applications. Equipment that needs sharp response like pressing systems, drilling machines, construction units and large mobile equipment benefits from this fast control behavior.
The PVG-150 is available with different mounting styles, shaft types and rotation. Multiple port locations, rear and top or bottom options help engineers to match the pump to existing hydraulic layout. This reduces installation time and simplifies system upgrades or replacements. The pump is built to last. Its efficient cooling path, strong internal build and high pressure capability reduces downtime. It supports long service intervals when maintained with proper filtration and recommended hydraulic fluids.
Technical Specifications
PVG FAMILY SPECIFICATIONS
| FRAME SIZE MODEL | B-FRAME | C-FRAME | D-FRAME | ||||||
| PVG-048 | PVG-065 | PVG-075 | PVG-100 | PVG-130 | PVG-150 | PVG-180 | |||
| DRIVE | Maximum (RPM) | 2700 | 2700 | 2700 | 2400 | 2400 | 2400 | 2400 | |
| Minimum (RPM) | 600 | 600 | 600 | 600 | 600 | 600 | 600 | ||
| Torque to turn shaft (ft. lbs.) | 9 | 9 | 9 | 24 | 24 | 40 | 50 | ||
| Rotational Moment of Inertia (lbs.-in2) | 21 | 21 | 21 | 50 | 47 | 150 | 152 | ||
| OUTPUT1 | Pressure (PSIA) | Peak | 5800 | 5800 | 4250 | 5800 | 4250 | 5800 | 5800 |
| Continuous | 5000 | 5000 | 3750 | 5000 | 3750 | 5000 | 5000 | ||
| Minimum | 100 | 100 | 100 | 100 | 100 | 100 | 100 | ||
| Nominal Volume (GPM) at 1800 RPM and Rated Pressure For Full Displacement | 21.1 | 28.8 | 33.3 | 42.4 | 57.6 | 63.0 | 78.0 | ||
| CASE2 | Maximum Pressure (PSI) w/ Standard Shaft Seal | 25 | 25 | 25 | 25 | 25 | 25 | 25 | |
| Minimum Drain Line Hose Size | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | ||
| CONTROLS3 | Minimum Pressure (PSI) | Pressure Controls – Minimum Compensator Setting | 200 | 200 | 200 | 200 | 200 | 250 | 250 |
| Volume Controls (VS, VM) – Minimum Pilot Pressure | 500 | 500 | 500 | 500 | 500 | 500 | 800 | ||
| Maximum Pilot Pressure (PSI) | Volume Control – VS | 600 | 600 | 600 | 600 | 600 | 600 | N/A | |
| Volume Control – VM | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | ||
| Stroking Rate (MSEC) at Rated Pressure, Pressure Controls (Minimum) | On Stroke | 40 | 40 | 40 | 40 | 40 | 45 | 45 | |
| Off Stroke | 50 | 50 | 50 | 50 | 50 | 60 | 60 | ||
| Volume Controls (VS, VM) | On Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | |
| Off Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | ||
| FLUID4 | Viscosity (SSU) | Minimum | 65 | 65 | 65 | 65 | 65 | 65 | 65 |
| Maximum | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | ||
| TEMPERATURE5 | Fluid Operating Range (F˜) | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | |
| Fluid Minimum Starting (F˜) | -40 | -40 | -40 | -40 | -40 | -40 | -40 | ||
| Fluid Maximum at Case Drain Port (F˜) | 230 | 230 | 230 | 230 | 230 | 230 | 230 | ||