PVG-150 Variable Displacement Axial Piston Pump
PVG-150 Variable Displacement Axial Piston Pump
- Series: PVG Pump
- Displacement 100 – 150 cc/rev
- Nominal Pressure 300 Bar
- Maximum Pressure 400 Bar
- Maximum Speed 2000 – 3000 RPM
- High-Pressure Pump
- Open Circuit Pump
Share Product:
PVG-150 Variable Displacement Axial Piston Pump
PVG-150 Variable Displacement Axial Piston Pump
Technical Specifications PVG-150 Axial Piston Pump
NOMINAL DIMENSIONS
| Frame Size |
Length | Width | Height | Weight | Face Mounting | ||||
| in. | mm | in. | mm | in. | mm | lbs | kg | ||
| D | 14.2 | 360,7 | 7.9 | 200,7 | 8.1 | 205,7 | 171 | 78 | SAE “D” 4 Bolt |
NOMINAL OPERATING PARAMETERS
| Theoretical Maximum Displacement | in^3/rev | 9.16 |
| ml/rev | 150,0 | |
| Rated Continuous Pressure | psi | 5000 |
| bar | 344,8 | |
| Peak Pressure | psi | 5800 |
| bar | 400,0 | |
| Flow Rate at 1800 RPM, rated continuous pressure & 14.7 psi (1.01 bar abs) inlet conditions | gpm | 63.0 |
| l/min | 238,5 | |
| Maximum Speed | rpm | 2400 |
| Power Input at rated continuous pressure & 1800 rpm | hp | 215 |
| kW | 160,4 |
Technical Specifications
PVG FAMILY SPECIFICATIONS
| FRAME SIZE MODEL | B-FRAME | C-FRAME | D-FRAME | ||||||
| PVG-048 | PVG-065 | PVG-075 | PVG-100 | PVG-130 | PVG-150 | PVG-180 | |||
| DRIVE | Maximum (RPM) | 2700 | 2700 | 2700 | 2400 | 2400 | 2400 | 2400 | |
| Minimum (RPM) | 600 | 600 | 600 | 600 | 600 | 600 | 600 | ||
| Torque to turn shaft (ft. lbs.) | 9 | 9 | 9 | 24 | 24 | 40 | 50 | ||
| Rotational Moment of Inertia (lbs.-in2) | 21 | 21 | 21 | 50 | 47 | 150 | 152 | ||
| OUTPUT1 | Pressure (PSIA) | Peak | 5800 | 5800 | 4250 | 5800 | 4250 | 5800 | 5800 |
| Continuous | 5000 | 5000 | 3750 | 5000 | 3750 | 5000 | 5000 | ||
| Minimum | 100 | 100 | 100 | 100 | 100 | 100 | 100 | ||
| Nominal Volume (GPM) at 1800 RPM and Rated Pressure For Full Displacement | 21.1 | 28.8 | 33.3 | 42.4 | 57.6 | 63.0 | 78.0 | ||
| CASE2 | Maximum Pressure (PSI) w/ Standard Shaft Seal | 25 | 25 | 25 | 25 | 25 | 25 | 25 | |
| Minimum Drain Line Hose Size | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | #16 SAE | ||
| CONTROLS3 | Minimum Pressure (PSI) | Pressure Controls – Minimum Compensator Setting | 200 | 200 | 200 | 200 | 200 | 250 | 250 |
| Volume Controls (VS, VM) – Minimum Pilot Pressure | 500 | 500 | 500 | 500 | 500 | 500 | 800 | ||
| Maximum Pilot Pressure (PSI) | Volume Control – VS | 600 | 600 | 600 | 600 | 600 | 600 | N/A | |
| Volume Control – VM | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | ||
| Stroking Rate (MSEC) at Rated Pressure, Pressure Controls (Minimum) | On Stroke | 40 | 40 | 40 | 40 | 40 | 45 | 45 | |
| Off Stroke | 50 | 50 | 50 | 50 | 50 | 60 | 60 | ||
| Volume Controls (VS, VM) | On Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | |
| Off Stroke | 250 | 250 | 250 | 250 | 250 | 250 | 250 | ||
| FLUID4 | Viscosity (SSU) | Minimum | 65 | 65 | 65 | 65 | 65 | 65 | 65 |
| Maximum | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | ||
| TEMPERATURE5 | Fluid Operating Range (F˜) | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | 14 to 190 | |
| Fluid Minimum Starting (F˜) | -40 | -40 | -40 | -40 | -40 | -40 | -40 | ||
| Fluid Maximum at Case Drain Port (F˜) | 230 | 230 | 230 | 230 | 230 | 230 | 230 | ||